INC-169012 · Issue 651257
VMWare workspace One Mobile support added
Resolved in Pega Version 8.7
Support has been added for the VMWare workspace One Mobile app by updating the BrowserUtilsRuntime file to add the necessary user agent.
INC-169203 · Issue 646097
Robotics Desktop Automation correctly runs on subsequent tabs
Resolved in Pega Version 8.7
When using Customer Service (CRM) to call Robotics Desktop Automation (RDA) from a data page, closing the first interaction tab after the RDA automation was completed resulted in the automation not being triggered for the second tab. If the first tab was not closed, the automation on the second worked as expected. Investigation showed the attachOnUnload was unregistering the client actions for all the open tabs and the attachOnLoad was not being called on reload. This has been resolved by updating attachOnLoad so it is now called with InvokeOnReload as 'true' to register client action for the tab in focus.
INC-169545 · Issue 649519
Localization updated for decimal slider
Resolved in Pega Version 8.7
When using the Indonesian locale, selecting the range on a slider which allowed selection of a decimal / double value that was then displayed in another textbox caused the value to increase incrementally and the slider always showed the end max. Investigation showed that this was caused by the handling of the comma decimal separator used in Indonesia, and has been resolved by updating the handling to ensure the slider value is converted to the respective locale.
INC-169796 · Issue 649263
Null check added for pyModes setting
Resolved in Pega Version 8.7
The column filtering function was not working after update from Pega 8.1 to Pega 8.5. This was traced to pyModes being set as null for page group properties, and has been resolved by adding a null check before adding the type to avoid getting an improper result from the Formatter Rule-Utility-Function.
INC-169866 · Issue 653548
View content type updated to FIELD
Resolved in Pega Version 8.7
After update table grids were not visible in the UI for some operators while other operators with the same access group were able to see the same table with the result rows. Investigation showed that the personalized view stored in 8.1.x did not have a content type set, causing all of the columns to be hidden after upgrade to 8.4+ due to the personal view not matching with the design time view. To resolve this, the content type has been updated to FIELD for views.
INC-170258 · Issue 645043
Removed unneeded query parameter in UI
Resolved in Pega Version 8.7
When using an Ajax container without a dynamic container, a refresh harness / section event call related to pyBlockUnregisteredRequests was not being properly registered, resulting in a 403 error and the message "Unregistered request encountered ..". This was traced to a "pyDataTransform=" query parameter that was present in the PZPEGA_UI_MICRODC file, and the parameter has been removed to resolve this issue.
INC-170918 · Issue 653216
DateTime property handling revised for future date with daylight savings time
Resolved in Pega Version 8.7
A DateTime property was changing each time the local action refreshed. Investigation showed this was a missed use case related to recent work to correct an issue with a 1 day discrepancy for non-template DateTime. The previous update to use the default time zone when generating markup in non-template for the date property while the datetime property uses the server time zone has been further refined to handle formatting the date time when the year is greater than 2037 and combined with daylight savings time. This will be resolved by setting the correct date before returning the moment object if the year is greater than 2037 for the date time control using display mode as date.
INC-171121 · Issue 648130
Filter popup persists correctly
Resolved in Pega Version 8.7
When the Apply filter option was selected for a table configured with a page list property as source, the filter popup appeared on the screen but disappeared after 3 to 4 seconds. This has been resolved by enabling the stretch for tabs option in the layout group.
INC-171352 · Issue 653691
Focus set correctly on the modal window in theme-Cosmos
Resolved in Pega Version 8.7
In theme-Cosmos with touch enabled, clicking on a button to open a modal window set the focus on the background instead of in the modal window, forcing tabbing through the full page to reach the modal window. This was traced to the templates not using the pzModalCancel control which has the necessary container_close for the modal dialog close icon, and has been resolved by adding a check to set the focus correctly.
INC-171663 · Issue 655245
MashUp dynamic parameters article updated
Resolved in Pega Version 8.7
The documentation for MashUp best practices has been updated to clarify that dynamic parameters sent from the client side using "pega.web.api.setAuthenticationParameters" API will be sent as part of the query parameters and won't be part of the encrypted hash as this hash is generated on the server end while generating the mashup code in the mashup channel.