SR-B12737 · Issue 282869

Resolved harness error after using pagination 'load more'

Resolved in Pega Version 7.3

After using the Pagination 'load more' option and clicking on any of the newly loaded items, a blank harness was opened. This was traced to missing change tracking data for the newly loaded rows, and has been corrected.

SR-B12770 · Issue 285068

Text areas display OOB error message as expected

Resolved in Pega Version 7.3

In the Text area control, the Pega OOB error message was not generated when there was no value in the required text area. This was an issue with minimum characters validation not considering an empty string to be a valid one, and has been corrected.

SR-B12783 · Issue 285395

Performance improvements for Data Designer Visualizer

Resolved in Pega Version 7.3

In order to improve performance of the Visualizer feature of the data designer, the loading behavior has been changed. Previously, the RD being executed for each node in the graph to get the reference properties was defer loaded; this potentially caused issues if the data was still being loaded in the background for the visualizer and an attempt was made to open BodySite. To fix this issue, the defer loading has been removed and the data will load on click of the "visualizer" button.

SR-B12857 · Issue 285462

Repaired REST Connections with proxy

Resolved in Pega Version 7.3

After upgrade, connections to external internet websites/services were failing when using a proxy. This has been fixed.

SR-B13040 · Issue 293380

Improved reliability for GetReference API

Resolved in Pega Version 7.3

A sporadic issue with the OOB getReference API caused a failure in obtaining the absolute reference for a parameterized data page. This was caused by a race condition in the page handler, and synchronization has been improved to ensure the proper name will be set into the data page.

SR-B13040 · Issue 293526

Null DPI check added for async page load

Resolved in Pega Version 7.3

A null pointer exception was being generated when a data page was being loaded from the asynchronous cache and some exception occurred while switching the access group or getting a definition. To avoid this, a check has been added for a null DPI.

SR-B13315 · Issue 284499

Accessibility updated for flow action label

Resolved in Pega Version 7.3

Accessibility tools such as JAWS were not reading out the flow action label. This has been fixed.

SR-B13315 · Issue 284499

Accessibility updated for flow action label

Resolved in Pega Version 7.3

Accessibility tools such as JAWS were not reading out the flow action label. This has been fixed.

SR-B13450 · Issue 284622

Null check added to joins of UserWorkList columns

Resolved in Pega Version 7.3

When attempting to join a pyUserWorkList Report definition with work class properties, blank values in the pyUserWorkList columns caused a Null Pointer exception on click of the filter icon for joined class properties/columns. This has been resolved by adding a null check.

SR-B13517 · Issue 293343

Icon alignment fixed in grids with skin inheritance

Resolved in Pega Version 7.3

The Header Title and the Collapsible Icon of a grid were misaligned due to an error in skin inheritance. The pzTemplateNewSkin1 legacy standard format has been changed to correct this.