Skip to main content

Resolved Issues

View the resolved issues for a specific Platform release.

Go to download resolved issues by patch release.

Browse release notes for a selected Pega Version.

NOTE: Enter just the Case ID number (SR or INC) in order to find the associated Support Request.

Please note: beginning with the Pega Platform 8.7.4 Patch, the Resolved Issues have moved to the Support Center.

SR-A4799 · Issue 213996

Frame resize resolved for SFDC Process Extender Bulk Processing

Resolved in Pega Version 7.2

The list and flow actions frames were not resizing properly in SFDC Process Extender Bulk Processing. This was caused by an 'access denied' error thrown if the top frame is not a PRPC frame, and the frameset method has been updated with a check to handle this issue.

SR-A5821 · Issue 214777

Included sections now added as referenced rules

Resolved in Pega Version 7.2

When including one section in another section with the page context as "Use clipboard page", the included section was not being correctly added to the pxRuleReferences page list when the embedded Page property of the section class was set as the using page. RUF pzValidateSectionIncludes has now been modified to consider the embedded Page property of the section class while adding the section in referencing rules.

SR-A1408 · Issue 206581

Localization added for @baseclass field values on iPad Fat Lists

Resolved in Pega Version 7.2

When using localized field values in the Fat List mode on an iPad, the RUF GenerateCellContent wasn't localizing the value but instead directly displayed the pyValue (i.e. the value entered for Value under Cell properties). This was due to the data-attribute-name not being localized for field values created only at @baseclass, and has been resolved.

SR-A7290 · Issue 216208

Made autocomplete field visible for mobile

Resolved in Pega Version 7.2

There was a problem with the visibility of the autocomplete field when used for add/remove buttons on mobile. The webkit-transform function was updated for smoother transition.

SR-A6422 · Issue 216542

Made busy icon visible during data upload wait

Resolved in Pega Version 7.2

The Busy Indicator was not being displayed during the wait period following the uploading of multiple records at a time from an Excel sheet to a flow action. This caused confusion about whether the process was still running. The issue was caused by poor positioning of the busy icon in a non-visible part of the screen, and the calculations for its location have been updated.

SR-A7868 · Issue 217588

Modified generateformat for use with Microsoft Internet Explorer 11 Compatibility Mode

Resolved in Pega Version 7.2

When Compatibility Mode was enabled in Microsoft Internet Explorer 11, navigating away from a decimal field containing a valid numeric value generated an error stating that the number was not a valid decimal value. This was due to the compatibility mode of Microsoft Internet Explorer using a generateformat method which inserted ' ' if the value was empty, and has been fixed by modifying PZGENERATEFORMAT RUF to compensate for this.

SR-A6521 · Issue 216380

Removed correspondence classname case sensitivity

Resolved in Pega Version 7.2

An error was generated when trying to save correspondence with value 'lookup classname' in source editor. Designating the value as a className worked as expected. This was caused by the innerHTML being set inside the ckeditor, forcing the attribute names to be small and therefore fail validation. To solve this, the presubmit function has been updated to maintain case and allow the classname to be entered in a case insensitive manner (i.e., even if you enter classname before submit, the classname will be replaced as className) and the file can be checked in.

SR-A3593 · Issue 210962

Removed forced validation for empty strings during switch to Other Actions

Resolved in Pega Version 7.2

Switching to Other Actions was forcing required fields. To fix this, a check has been added to skip validation for empty strings when switching between flow actions.

SR-A4436 · Issue 213360

Resolved premature validation while tabbing in Microsoft Internet Explorer

Resolved in Pega Version 7.2

Using the Microsoft Internet Explorer browser on a user portal, the Property Required validation was firing when the operator tabbed into the field. This was caused by an element firing on refocus, and a check has been added to the ui_events file to properly handle the refocus.

SR-133715 · Issue 204978

RTE <br> handling resolved when using pega:when = false

Resolved in Pega Version 7.2

Inconsistent behavior was seen when using rich text editor in paragraph rule if the pega:when was false. This was an issue with the handling of the
tags under this condition, and has been resolved.

We'd prefer it if you saw us at our best.

Pega.com is not optimized for Internet Explorer. For the optimal experience, please use:

Close Deprecation Notice
Contact us