SR-B9780 · Issue 286188
work object progression fixed after cancel/close with errors
Resolved in Pega Version 7.3
A repeat grid's modal dialog could be cancelled or closed without correcting the validation error fired by a field in it, but afterwards no actions could be performed on that specific work object even if the error was then fixed. This was caused by Messages added onto the pyWorkPage not being cleared on click of cancel if followed by clicking on grid pagination actions, and has bene resolved by changing the cancelmodal method from ModalButtonSubmit to ModalButtonCancel.
SR-B9879 · Issue 278433
RTE linkbox input handling corrected for modal windows
Resolved in Pega Version 7.3
In an "inline editable" grid with 'click to edit' selected, clicking on the RTE link inputbox in the modal window caused the grid row to be submitted as if the click took place outside the grid. The gridEventHandler has been updated to correct this.
SR-B9916 · Issue 283675
Hyperlink works on custom HC login page
Resolved in Pega Version 7.3
In a Hybrid Client App with a custom login page, a simple HTML link which calls the function to load the mashup code for the gadget worked in the browser but not in the HC. This was caused by window.open not working inside HC. To enable this, the _launchPopup api of compositegadgetmgr.js has been modified to use launchbox.Browser.start instead of window.open and the isCookieConsentRequired API has been updated to return false for popup case.