INC-197358 · Issue 695308
Resolved finish assignment screen freeze
Resolved in Pega Version 8.7.1
In some assignments of several flows, when the processing was done (finish assignment) the screen only displayed the loading logo. The only way to proceed was by refreshing the browser. The browser console showed the error "Uncaught TypeError: Cannot read properties of null (reading 'undefined') at setTargetValuesSuccess (expression_calculation_1480665478.js!!.js:1) at k". The error did not occur when using Live UI privileges. This has been resolved by updating the expression calculation.
SR-115749 · Issue 167027
Support added for custom filtering and refresh inside a Repeat Grid
Resolved in Pega Version 7.1.7
If a dropdown control was placed in the column header of a repeating grid to work as a filter and perform a section refresh for the list (based on a column present in the list, but not displayed in the grid), checking the option to freeze the column headers (and use a fixed height/width) caused the dropdown to no longer work and no refresh action could be triggered. This was caused by a second hidden dropdown in the grid with the fixed header configuration that overwrote the selected value in the ASYNC request that is sent when the dropdown value changes. To remedy this, changes were made in the HTML generation to make the hidden header input disabled. This works only when configured as "auto": the control generation logic overwrites all readonly conditions to true if the dropdown is configured as "Editable".