INC-201372 · Issue 694015

Accessibility improvements for Cosmos Case Life Cycle

Resolved in Pega Version 8.6.3

Keyboard navigation has been updated to improve accessibility for the case life cycle component. For the "Show stages with expandable steps" configuration, code has been added to hide the steps container when tabbing through the stages. For the "Show stages with steps as overlay" configuration, the "Use form navigation (by tab)" option has been enabled for every repeating dynamic layer inside the steps overlay.

INC-201739 · Issue 694505

Switch from Pega base64 utility to java.util.Base64.getEncoder

Resolved in Pega Version 8.6.3

An on-premises Web Application Firewall (WAF) was interpreting the characters "%0a" in the Pega auto-generated URL as an "HTTP Response Splitting" attack. As a result communications were intercepted and a 403-error screen was shown. In addition, the characters %250A were interpreted as LF (line feed) or \n in the refreshFor hash generation. To resolve this, an update has been made to use java.util.Base64.getEncoder().encodeToString instead of the Pega base64 utility.

INC-201929 · Issue 692850

Removed incorrect field validation errors

Resolved in Pega Version 8.6.3

When integer controls in a section were configured as required field, clicking on the field but not entering any value resulted in the prompt for the required field validation "Value cannot be blank", and any attempts to add a positive integer using number keypad after that resulted in the repeated validation error. This has been resolved by updating pzpega_control_textinput.

INC-202218 · Issue 692877

Input from Microsoft Windows keyboard numpad enabled

Resolved in Pega Version 8.6.3

After entering a currency amount using the right side number pad keys on a Microsoft Windows keyboard, a mandatory field validation was being thrown on what appeared to be a correct input. This was due to an if condition in the keyup function that caused entries from the right side number keys to not be considered as input, and has been resolved by removing the condition from the pzpega_control_textinput file.

INC-205566 · Issue 697058

Ensured correct context for multi-select

Resolved in Pega Version 8.6.3

When using multi-select controls, there was an intermittent issue with selecting values using a mouse click. Using the tab key worked as expected. This was traced to the focus being event triggered multiple times so pega.ctx.dom returned undefined values in the second call.This has been resolved by focusing the target element before creation of capsule to ensure the context remains the same.

INC-206485 · Issue 698399

DOM Purifier updated to allow new tags

Resolved in Pega Version 8.6.3

Snippets were visible after being added and published, but after editing the same content ID it was converted to a text file. This was traced to the DOM Purifier plugin removing tags which were not in default list, and has been resolved by adding the ADD_TAGS option in the DOM purifier to accept tags.

INC-217655 · Issue 723565

Resolved validation check freeze for Dynamic Layout Group

Resolved in Pega Version 8.7.3

After creating a multi-step form where step 1 had a Dynamic Layout Group(tabbed) that used form fields configured with validations, clicking next with empty/invalid values in the form intermittently caused the screen to freeze and a javascript exception was logged. This was traced to a missed use case related to templates in the childNode, and has been resolved by adding the necessary safe checks in lgtemplate and lgcelltemplate.

INC-218855 · Issue 718834

DSS added to control section collapse on refresh

Resolved in Pega Version 8.7.3

After update from 8.5, using dynamic layouts that included certain controls (autocomplete/text/dropdown) configured with Refresh-Other Section -> Parent / Top Level Section such as a pyCaseActionArea with Event 'On Change' showed a different behavior: entering a value in the configured text/auto-complete field that leads to the refresh of the top level section will collapse all expanded sections if there is a refresh trigger within the embedded section or dynamic layout of the collapsible layouts. In order to control this behavior, a new DSS has been introduced. By default HonourExpandWhenOnRefresh (owning ruleset Pega-UIEngine) will be set to false to maintain the current behavior of collapse on refresh, while setting it to true will use the older behavior of maintaining expanded sections.

INC-223222 · Issue 723634

Corrected apiContext when using bulkActions

Resolved in Pega Version 8.7.3

Row selections in the multi-selection table were intermittently not working after opening a table with bulk actions enabled. Investigation showed that opening a table with bulkActions enabled and then navigating to a table where bulk actions are not available but multi-select is enabled led to functions like setSelectedRows and getSelectedRows still being available in apiContext. This has been resolved by correcting apiContext when bulkActions is enabled.

INC-225236 · Issue 725703

Corrected LiveDesignViewDisplay error handling

Resolved in Pega Version 8.7.3

When all rulesets were locked and a section was opened from Live UI in a portal, a "rule deleted" message appeared and it was confirmed the rule was deleted even though the rule was in locked ruleset. Investigation traced this to a pzLiveDesignViewDisplay call to pxChooseBestRuleSet which jumped to failure logic when "allow check out" was disabled, and this has been resolved by correcting the error handling in pzLiveDesignViewDisplay.