INC-149823 · Issue 608353
DX API returns properly referenced icon class for embedded page
Resolved in Pega Version 8.6
When using the DX API to build an Angular JS UI, the response returned from the GET /cases/{ID}/actions/{actionID} api did not return the iconStyle for an icon class that uses a property reference when the flow is on an embedded page. This has been resolved by adding code to set the correct context for pzAPICreateJsonForModes and pzAPICreateJsonForField RUF.
INC-149946 · Issue 609042
OpenIfStale updated to resolve optimistic locking race condition
Resolved in Pega Version 8.6
A race condition was created in optimistic locking by having two assignments save at overlapping times. This has been resolved by modifying the pzShowConflicts activity to use a version of openIfStale which will consider a workpage as stale even if the difference in pxUpdateDatetime is in milliseconds.
INC-149988 · Issue 608821
Upload with "Select File" works in Microsoft IE
Resolved in Pega Version 8.6
When using Microsoft Internet Explorer, uploading a document was failing on the first try when using the "Select File" button. The second attempt worked as expected. This was an unintended consequence of work done to enable attaching the same file after deleting it, and was related to Internet Explorer calling an "onChange" which caused the "pzAttachFileDDFileList" section which is used to display the attachments uploaded to not be properly refreshed. This has been resolved by updating the pzMultiFilePath control handling of the success and failure of the upload function call.
INC-150172 · Issue 611773
Updated class handling for View field security
Resolved in Pega Version 8.6
When using a defined View which returned a page and its fields and used an inherited custom work party definition, trying to update the pyWorkParty(Customer) by calling the "post /assignments/{ID}/{actionID}" did not work as expected when Field Security was ON. This was traced to the field security relying on the design time page class information stored in the list/group property, and has been updated to resolve the view fields using actual class information from the work page.
INC-152442 · Issue 616667
Check added for Create Access to attachment
Resolved in Pega Version 8.6
After restricting access for the attachments category in a CS application, the attachment was added without category and could not be opened. This was due to the Create Attachment access not being automatically created for all categories when privileges were added, and has been resolved by adding a step to check Create Access for attachments of the respective category.
INC-153688 · Issue 616917
Class name length limitation raised to 64 characters
Resolved in Pega Version 8.6
In order to support field audits on very long class names, FLAudit Class has been modified to allow a class Name length of 64 characters instead of the previous limit of 56.
INC-153801 · Issue 625946
Modified handling for updating SLA on Bulk Agent items
Resolved in Pega Version 8.6
While transferring SLA-configured assignments to the work basket using the Bulk Agent in background processing, the assignment handle of the SLA item was not getting updated to the work basket assignment handle. The error "duplicate key value violates unique constraint" was logged. This was due to the system not being able to dequeue the SLA item while it was locked by the Queue Manager as part of the background bulk processing, preventing the assignment handle from being updated on the SLA item. To resolve this, the system will perform a direct database open of the SLA item so the assignment handle is updated.
INC-154189 · Issue 617245
Harness used to determine read-only for button/text input
Resolved in Pega Version 8.6
If a button/text input was configured to always be editable in a section by using the /v1/cases/{ID}/pages/{pageID} API (say i.e PageID as Review), the button/text input was always returned as readonly. This was due to the API being hardcoded to return readonly info, and has been resolved by updating pzGetPageDetails to not force read-only and let the harness configuration decide the behavior.
INC-154778 · Issue 620907
Bulk actions filtering works in Spanish locale
Resolved in Pega Version 8.6
Filtering by only case type did not return any results when using the Bulk Transfer functionality with the Spanish locale. Investigation showed that the filter value case type had a field value set, but the localized value was not being checked in the pzPostFilterOperation in step 1 'when' condition. This has been resolved.
INC-154826 · Issue 614817
Enhanced handling for screen/non-screen/screen flow movement
Resolved in Pega Version 8.6
When using a screen flow where the last screen had a link to launch a section, a cancel button in the section that was configured with a data transform and a 'Finish Assignment' intended to move back to the screen flow did not work as expected. If a browser refresh was performed and then the cancel button was clicked, the Finish Assignment / return was triggered as expected. Because this configuration navigated to a non-screen flow, the attachOnLoad function did not load the parameter needed for maintaining error messages. This has been resolved by updating the navigation to handle this use.