INC-153877 · Issue 612370
Enhanced socket timeout logging
Resolved in Pega Version 8.4.4
In order to assist with diagnosing issues with socket timeouts such as a Data Flow Daily Run failing, logging to print the SocketTimeout value has been added when case info is enabled.
INC-154605 · Issue 615661
Date field correctly extracted for IMAP inbound email
Resolved in Pega Version 8.4.4
After upgrade, email-sourced cases were not being created correctly. Tracer showed the date field was blank, causing an error which was traced to the getReceivedDate being returned as null for the JavaMail AP even though the IMAP protocol was being used. This was an unintended side effect of work done to handle a throttling exception in the IMAP inbound email flow, and has been resolved by updating the system so that if the getReceivedDate is null, the date will be extracted from the mail header while processing dates in EmailMessageInfo class.
INC-158159 · Issue 622628
JobScheduler initialization timing adjusted
Resolved in Pega Version 8.4.4
DDS nodes were ending up in a deadlock condition on restart, preventing them from joining the cluster. This has been resolved by ensuring the JobScheduler initialization task waits for Search to start up.
SR-D96430 · Issue 561525
Updated visibility condition expression handling for decimal values
Resolved in Pega Version 8.4.4
After upgrade, any visibility condition expression failed to evaluate decimal values that used precision. When 0 (zero) was entered as a value in the input field, a button that was configured to show was visible as expected. When the value was entered as 0.0, the input failed and the button did not show. The problem did not happen "Run visibility condition on client" was enabled. Investigation showed this was an issue with how the When expression was evaluated and calculated within JspWhenEvaluate, and has been resolved.
INC-150689 · Issue 607157
Format specifier error resolved
Resolved in Pega Version 8.4.4
Errors were registered in PDC and stack for an Email Listener "Format specifier '%s" Exception. This was traced to a formatting error, and has been resolved.
INC-102005 · Issue 556731
Child case ID prefix preserved
Resolved in Pega Version 8.4.2
When configuring a case as a child case in App Studio, the case ID prefix was cleared out of the field on the Settings tab for the case type. Investigation showed that when the child case was added to the parent case in App studio, pzaddcasetypetoapp was called but the parent activities did not pass the CaseID parameter of the child case type. This caused the CaseID prefix of the child to be null and displayed as blank in the Settings and Application. This has been corrected by ensuring the system will get and set the parameter value.
INC-119754 · Issue 561523
Corrected 'when' rule context for GetCaseDetails
Resolved in Pega Version 8.4.2
The Pega REST API Get Method /cases{CaseID} failed if the Child Case was set with Manual instantiation using a 'when' rule. This was traced to the 'when' rule being resolved using @baseclass instead of the class of the case type, and has been resolved by updating the pzGetCaseDetails activity to evaluate the 'when' rule on the case page.
INC-120608 · Issue 573001
Temporary case creation from Cosmos resolved
Resolved in Pega Version 8.4.2
Creating a temporary case in Cosmos Portal was not working. Investigation showed that the pySkipCreateHarness and pyCreatesTemporaryObject properties were not populating properly on the D_StartingFlows data page, which was traced to the way openSelectedColumns API handles non-exposed columns. To resolve this, the system has been updated to use the openEngine API for opening starting flows if the pySkipNewHarness or pyCreatesTemporaryObject property values are null.
INC-121435 · Issue 563877
Handling added for null requiredskillcount on assignment
Resolved in Pega Version 8.4.2
If the property pxRequiredSkillCount was blank on an assignment when moved to a workbasket, it was never presented for Get Next Work. To resolve this, handling has been added which will change the null to 0 so the assignment is properly queued.
INC-127077 · Issue 564109
Busy indicator appears when uploading via Select
Resolved in Pega Version 8.4.2
After upgrade, the “loading symbol” (busy indicator) was not appearing while uploading large attachments using the Select button. This was a missed use case in recent changes to related to AsyncUpload, and has been resolved.