SR-122839 · Issue 185954

Audit entries properly suppressed

Resolved in Pega Version 7.1.8

Audit entries were being added to the history even after suppressing the same in the DT "FilterHistory" of the respective interaction class. When the "RemoveAssignmentByTicket" function called the activity "AddWorkHistory", the parameter workPage was not being sent. Because the system skipped the call to the decision tree, it was returned as 'true' each time. To resolve this, the system now passes "WorkObjectPageName" to ensure proper evaluation.

SR-122902 · Issue 182835

Shutdown issue with Tomcat resolved

Resolved in Pega Version 7.1.8

During shutdown, errors were reported on the App Server window. Shutdown did not complete and the App Server Window remained open. This was due to the "Shutdown" button/feature not properly terminating Tomcat. There was a workaround to manually close the Tomcat window, but the DNodeServiceListener has been modified to release all of the threads properly.

SR-122917 · Issue 182299

Resolved error in security change tracking

Resolved in Pega Version 7.1.8

If security change tracking was enabled using a declare trigger with a TrackSecurityChanges activity on the Operator class, adding a Data Transform ChangeTrackModel to track a number of properties on the operator record would create a PropertyIndex property and no further changes could be saved. This occurred in environments using the dynamic system setting "validateonsave" (set to true) which validates the property existence in the class hierarchy, but a validation error occurred on save because "pyPropertyIndex" is in the Embed-ModalParams class which was not accessible to Data-Admin-Operator-ID. To resolve this, the "pyPropertyIndex" has been moved to baseclass.

SR-123031 · Issue 182673

Corrected inheritance logic for ComputeSegment

Resolved in Pega Version 7.1.8

ComputeSegmentLogic activity logic was not considering inheritance path. This was an issue with having the run-time rule resolution at design-time, and has been changed to pass propagate the apply-to class to sub-activity calls so that it can pick up the right rule.

SR-123235 · Issue 183263

Additional localization for attachments functions

Resolved in Pega Version 7.1.8

Localization has been added in the attachments section for the "Attachment" link, "Attach URL", 'Add new party" in the work parties modal, and the "Save Draft" button.

SR-123242 · Issue 183215

Stage names now incuded in localization wizard

Resolved in Pega Version 7.1.8

Previously, Stage names were not picked up by the localization wizard unless each Case Type was saved in the application. An enhancement has been added to allow them to be localized more efficiently.

SR-123245 · Issue 185467

Resolved frame stack error with Flow GenerateAndProcessRequirements

Resolved in Pega Version 7.1.8

Flow GenerateAndProcessRequirements had an error in step Utility2 that generated a Frame stack error. This was caused by the method used for ClipboardObjectImpl.getThread(): in the case when owning thread is from a different requestor, it is possible that two requestors are simultaneously executing on the owning thread. In this case, the PRStackFrame push pop calls from both the requestors (foreground browser requestor and background declare trigger activity requestor) interfered with each other and caused the error. This has been fixed. / UpdateOpenCoveredTasks was causing null pointer exception due to the trigger activity, 'Work-Cover-. UpdateOpenCoveredTasks' not being available to this activity - the trigger is defined to run in background. Exceptions are thrown because the system was checking for messages on tempWorkPage page and tempWorkPage was being deleted in few cases. To fix this, a condition has been added to check whether tempWorkPage exists before checking for messages on it.

SR-123245 · Issue 185150

Resolved frame stack error with Flow GenerateAndProcessRequirements

Resolved in Pega Version 7.1.8

Flow GenerateAndProcessRequirements had an error in step Utility2 that generated a Frame stack error. This was caused by the method used for ClipboardObjectImpl.getThread(): in the case when owning thread is from a different requestor, it is possible that two requestors are simultaneously executing on the owning thread. In this case, the PRStackFrame push pop calls from both the requestors (foreground browser requestor and background declare trigger activity requestor) interfered with each other and caused the error. This has been fixed. / UpdateOpenCoveredTasks was causing null pointer exception due to the trigger activity, 'Work-Cover-. UpdateOpenCoveredTasks' not being available to this activity - the trigger is defined to run in background. Exceptions are thrown because the system was checking for messages on tempWorkPage page and tempWorkPage was being deleted in few cases. To fix this, a condition has been added to check whether tempWorkPage exists before checking for messages on it.

SR-123249 · Issue 184707

Stale stage completion checkmarks cleaned up

Resolved in Pega Version 7.1.8

When using a Split-For-Each shape with "Join" field set to "Iterate" and the Harness set to "TreeNavigation7" on a sub process tabbed screen Flow, the green tick marks which appear after completion of every stage in screen flow were not resetting for new items in the page list. Closing the workobject by clicking on red (X) mark and then reopening the same work object reset it properly. This was caused by missing logic to check whether FlowData should be reused or not, and has been fixed.

SR-123303 · Issue 185053

Corrected Case match rule reporting

Resolved in Pega Version 7.1.8

The Case match rule was not reporting results that were greater than the cut off score. This has been corrected by changing the rule RunDuplicateCasesReport to check on InsKey instead of pyID as InsKey is available for all pages of different classes where pyID is not.