SR-D33359 · Issue 505773

SelectAll properly applied to only the page selected

Resolved in Pega Version 8.2.4

In repeating grid, applying SelectAll on one page resulted in it being applied to the next page as well even though all records in the other page were not selected. Investigation showed that on change, the 'when' condition added to refresh the list was always false. To resolve this, the condition in section pzBulkProcessingCheckbox which refreshes the list once the checkbox is changed has been removed.

SR-D37444 · Issue 507038

WorkBasketGadget control updated for improved backwards compatibility

Resolved in Pega Version 8.2.4

After upgrade, the WorkBasketGadget Control was not retrieving the work queues. This was traced to a backwards compatibility issue introduced when greater security was put in place. The control WorkBasketGadget contains a call to pzEncryptURLActionString that was introduced in 8.x versions of the platform to encrypt URLs to avoid hijacking. The content of the URL relies on the pxRequestor.pxWorkGroup property, which is resolved using pega:reference tags. This approach was working in versions below 8.x, but these tags were not resolved at runtime. To correct this, requestorWorkGroup will be resolved as string and passed as a parameter instead of using pega:reference tags.

SR-D26785 · Issue 495892

Corrected error when persisting temporary work object

Resolved in Pega Version 8.2.4

When persisting a temporary work object using the Persist case shape, the internal assignment handle was not updated to include the work object's ID. Subsequent attempts to access the internal assignment (such as the "Edit" button on the Review Harness) resulted in errors. Investigation showed that when a temporary case was persisted, pyInternalAssignmentHandle was not getting recalculated after pzInsKey was updated. To resolve this, the configuration on the edit button has been modified to use .pxFlow(pzInternalCaseFlow).pxAssignmentKey which is what pyInternalAssignmentHandle declare expression was also returning.

SR-D32525 · Issue 505467

Dirty check added to offer save/discard changes when closing tab

Resolved in Pega Version 8.2.4

With the OOTB section enabled, performing a change in the form (changing a text value, selecting a option in a dropdown, etc.) and closing the case generated an unexpected alert indicating that the case was changed and the modifications were lost. This differs from the previous behavior of showing the section pyDirtyCheckConfirm which offered the opportunity to save the work. This was a missed use case and has been resolved by updating the system to perform a check for the dirty state when closing the interaction and show a modal dialog asking the user to choose either save/discard if dirty.

SR-D29832 · Issue 503225

Corrected image alignment for email case creation

Resolved in Pega Version 8.2.4

An issue with missing image styling when an email was sent to create a case was traced to the Owasp library stripping align attributes from the img tag. This has been fixed.

SR-D33966 · Issue 504607

Corrected accessibility error after resize

Resolved in Pega Version 8.2.4

From within a Case and on a screen displaying the Information and Audit tabs in a Layout group, it was possible to use a series of sequences that included resizing the browser and opening Audit to cause the information tab to no longer be accessible. This has been resolved by setting the transform value to 0 after completing the resize.

SR-D37757 · Issue 507967

Pulse delete icon repaired

Resolved in Pega Version 8.2.4

After upgrade, it was no longer possible to delete one's own comment in Pulse. This was traced to the section pzDeleteMessage having two dynamic layouts with icon as image configured. During runtime, this section was present in the DOM yet the icons were not visible when the conditions configured were returned as true. This was caused by an error in the generated java for the layout, and has been corrected.

SR-D18853 · Issue 503275

Visibility on client check removed to enable Pulse on click

Resolved in Pega Version 8.2.4

When Pulse was configured on click of a icon, the comment section was not visible. Investigation showed that at the time of DOM load, pyMessage property was not available in the DOM because 'Run visibility condition on client' was checked by default. Visibility on client checks have been removed to resolve this issue.

SR-D33491 · Issue 511727

Code fragment removed to resolve CookieDisabledException

Resolved in Pega Version 8.2.4

After upgrade, a CookieDisabledException occurred after a post activity was invoked in the single sign-on (SSO) authentication service. This was traced to the site using the deprecated flag "redirectguests" as part of SSO-based login for mashup usecases. This flag was used to check if a cookiedisabled exception was thrown or not, and if there was no cookie, if a requestor was authenticated in first request. However, the flag has been removed as part of work done to omit the Cookie support check on Mobile App UAs. Code that supported the use of this flag remained after that work and led to the exception being generated, but has now been removed as well.

SR-D43811 · Issue 511921

Code fragment removed to resolve CookieDisabledException

Resolved in Pega Version 8.2.4

After upgrade, a CookieDisabledException occurred after a post activity was invoked in the single sign-on (SSO) authentication service. This was traced to the site using the deprecated flag "redirectguests" as part of SSO-based login for mashup usecases. This flag was used to check if a cookiedisabled exception was thrown or not, and if there was no cookie, if a requestor was authenticated in first request. However, the flag has been removed as part of work done to omit the Cookie support check on Mobile App UAs. Code that supported the use of this flag remained after that work and led to the exception being generated, but has now been removed as well.