INC-182776 · Issue 666940
CheckFlowDependencies updated for auto-instantiated child cases
Resolved in Pega Version 8.6.2
A parent case with more than one child case was producing an unexpected behavior during the child case creation process. The first child case was instantiated at the correct point of the case stage based on its dependency condition, but the following cases were instantiated at the same point where the first child case was created irrespective of the dependency conditions defined in the other child cases. Investigation showed that the pxCheckFlowDependencies activity called from the Resolve activity was removing the named pages "pyTopCaseMap" "pyTopCaseWork" which are required for starting and validating configured auto-instantiate child cases in the pzCanStart function. To resolve this, an update has been made to CheckFlowDependencies which will use the activity "pzResolveCaseHierarchyMap" for removing the "pyTopCaseMap" and "pyTopCaseWork" pages based on DependencyType.
INC-183751 · Issue 665892
Improved text contrast for Attach Content button
Resolved in Pega Version 8.6.2
In order to improve accessibility, the contrast between text and background colors has been increased for the Attach Content button by updating pzMultiDragDropControlStandard to change the color from gray to black in function pzInitHTML5DD().
INC-184271 · Issue 668412
Portal Header persists appropriately
Resolved in Pega Version 8.6.2
The Portal header was disappearing immediately after case attachments were opened from the right sidebar and did not reappear even after refresh. This was traced to the absence of pd(event), and has been resolved by adding pd(event) to the onclick attribute in the anchor tag in the attachment UIKit rules.
INC-184300 · Issue 666156
Deprecated status removed from StartCaseType
Resolved in Pega Version 8.6.2
After updating from Pega v8.4 to v8.6, guardrail warnings were seen for the deprecated pxStartCaseType flow rule. This occurred for old case types created prior to v8.5. A utility has already been provided to upgrade the case type to include create stage, but this warning has been resolved by removing the deprecated status on pxStartCaseType to allow processes to proceed without a guardrail warning.
INC-186654 · Issue 669114
GetStatusChanges performance improvements
Resolved in Pega Version 8.6.2
Performance issues were seen when running the GetStatusChanges report. This was traced to the filtering methods used, and has been resolved by updating the report definition and enhancing the filtering conditions.