SR-D68235 · Issue 534781

Stale WorkSearchPreference data cleared when switching apps

Resolved in Pega Version 8.3.3

The D_pyWorkSearchPreferences data page data was not refreshing while switching between apps, causing stale data to be populated under the case search dropdown for all the applications after switching the application from one to another. This has been resolved by removing the D_pyWorkSearchPreferences data page as part of pzProcessApplicationSwitch.

SR-D88141 · Issue 550008

TemplateButton field correctly set read-only

Resolved in Pega Version 8.3.3

When a control was added to a section using the DX API, a pyTemplateButton field was added to the XML definition of the section with read-only set to 'false'. This has been corrected so the pyTemplate Button field does not allow input.

SR-D76291 · Issue 547839

Updated retry logic for S3 AddAttachmentFromEmail

Resolved in Pega Version 8.3.3

When using the AddAttachmentFromEmail activity with S3 repositories, performing an obj-save on the data-workattach-file page executes a deferred save while also saving the file into the repository. if the data was inserted into S3 successfully but encountered an issue when saving the related data-work-attach-file page, the system was trying to call the save operation again. This tried to insert the duplicate attachment again to S3, causing an error on that side of the process. To resolve this, the duplicate Obj-Save functionality in AddAttachmentFromMail Activity has been removed.

INC-167606 · Issue 665868

Updated ConfirmHarness handling for case type creation

Resolved in Pega Version 8.5.5

If a new case type was created with the initialization stage and there were no assignments in the case type, the /cases API did not return a NextPageID in response. This has been resolved by setting the pyConfirmHarness parameter before calling addworkobject.

INC-168368 · Issue 651080

Correct flow actions loaded in multi-thread portal refresh

Resolved in Pega Version 8.5.5

The member authentication screen was displaying an incorrect flow action on doing browser refresh after creating a new interaction. Refresh is a special case where the parameter retention is different across single-threaded & multi-threaded portals alongside the execution order of activities. In this case, this inconsistency occurred in a multi-threaded portal when newAssignPage had the information to load the proper assignment but the parameter indicated an old index. This has been resolved by adding 'when' conditions to to populate and pass the correct references and labels and to honor the Param.TaskIndex set and sent by UI activities so it's retained in case of multi-thread portals.

INC-169636 · Issue 649730

WorkObjects security update

Resolved in Pega Version 8.5.5

Cross-site scripting protections have been updated for WorkObjects.

INC-170514 · Issue 653761

Lock conflict resolved for AssignmentCheck

Resolved in Pega Version 8.5.5

The error "Unable to unlock this work object" sporadically appeared in both the runtime log and Pega RULES log when the robot was trying to create a case in Pega using an API call. Investigation showed that as the case was created, it was pulled by another robot (another requestor) which was using the GetAssignments API. This caused the perform assignment check to fail. To resolve this, a 'when' rule has been added to the performAssignmentCheck Activity.

INC-171842 · Issue 664385

Visible element populated for field value controls

Resolved in Pega Version 8.5.5

When implementing a section which had several labels with visible when conditions, this is not reflected in the DX API Get Assignment View. This has been resolved by adding a visible element.

INC-172584 · Issue 654923

Deprecated NewWorkGadget registered for BAC

Resolved in Pega Version 8.5.5

Logging in through the Administrator portal and launching a new project resulted in a blank screen. Investigation traced this to the Create New Work action called in the NewWorkGadget control; because the NewWorkGadget is no longer used by Pega, it was not registered for use with BAC. To resolve this, validations have been added for Control: NewWorkGadget, and the control has been marked as deprecated.

INC-174045 · Issue 650735

DSS added to control merge strategy

Resolved in Pega Version 8.5.5

The activity page merge option takes merge strategy as input and supports different merge strategy options like 'Replace', 'Update' etc. Previously, V1 DX APIs defaulted to REPLACE as the merge strategy; this has been updated to support both 'REPLACE' and 'UPDATE' merge strategies which can be controlled with the new DSS "v1MergeStrategy". The DSS to customize the merge strategy for v2 APIs is 'v2MergeStrategy', which also takes the values 'REPLACE' and 'UPDATE', which are for merge strategy '1' and '3' respectively. The default strategy from Pega 8.6 forward is 'UPDATE' and any other value other than the above two values will be considered as 'UPDATE'.