INC-175630 · Issue 653865
Application selections only announced when visible
Resolved in Pega Version 8.4.5
The elements of the application switcher were being announced by the NVDA screen reader even when toggled off, i.e. not visible. The issue was occurring because the focus was remaining at the search bar even after closing the app switcher window, and has been resolved by adding the necessary logic to switch the focus.
INC-176091 · Issue 652122
Busy indicator correctly resolves with Microsoft Internet Explorer upload
Resolved in Pega Version 8.4.5
When using Microsoft Internet Explorer to upload documents, the busy indicator was not resolving after the file was attached. This was due to a missed use case in work done around the timing of the busy indicator when attaching multiple files, and has been resolved by modifying PzMultiFilePath to ensure the busy Indicator is removed when the file count is zero.
INC-177183 · Issue 656492
Refresh assignment checks updated
Resolved in Pega Version 8.4.5
Additional privilege checks have been added to refresh assignment.