SR-D33359 · Issue 505773

SelectAll properly applied to only the page selected

Resolved in Pega Version 8.2.4

In repeating grid, applying SelectAll on one page resulted in it being applied to the next page as well even though all records in the other page were not selected. Investigation showed that on change, the 'when' condition added to refresh the list was always false. To resolve this, the condition in section pzBulkProcessingCheckbox which refreshes the list once the checkbox is changed has been removed.

SR-D37444 · Issue 507038

WorkBasketGadget control updated for improved backwards compatibility

Resolved in Pega Version 8.2.4

After upgrade, the WorkBasketGadget Control was not retrieving the work queues. This was traced to a backwards compatibility issue introduced when greater security was put in place. The control WorkBasketGadget contains a call to pzEncryptURLActionString that was introduced in 8.x versions of the platform to encrypt URLs to avoid hijacking. The content of the URL relies on the pxRequestor.pxWorkGroup property, which is resolved using pega:reference tags. This approach was working in versions below 8.x, but these tags were not resolved at runtime. To correct this, requestorWorkGroup will be resolved as string and passed as a parameter instead of using pega:reference tags.

SR-D26785 · Issue 495892

Corrected error when persisting temporary work object

Resolved in Pega Version 8.2.4

When persisting a temporary work object using the Persist case shape, the internal assignment handle was not updated to include the work object's ID. Subsequent attempts to access the internal assignment (such as the "Edit" button on the Review Harness) resulted in errors. Investigation showed that when a temporary case was persisted, pyInternalAssignmentHandle was not getting recalculated after pzInsKey was updated. To resolve this, the configuration on the edit button has been modified to use .pxFlow(pzInternalCaseFlow).pxAssignmentKey which is what pyInternalAssignmentHandle declare expression was also returning.

SR-D32525 · Issue 505467

Dirty check added to offer save/discard changes when closing tab

Resolved in Pega Version 8.2.4

With the OOTB section enabled, performing a change in the form (changing a text value, selecting a option in a dropdown, etc.) and closing the case generated an unexpected alert indicating that the case was changed and the modifications were lost. This differs from the previous behavior of showing the section pyDirtyCheckConfirm which offered the opportunity to save the work. This was a missed use case and has been resolved by updating the system to perform a check for the dirty state when closing the interaction and show a modal dialog asking the user to choose either save/discard if dirty.

SR-D29832 · Issue 503225

Corrected image alignment for email case creation

Resolved in Pega Version 8.2.4

An issue with missing image styling when an email was sent to create a case was traced to the Owasp library stripping align attributes from the img tag. This has been fixed.

SR-D33966 · Issue 504607

Corrected accessibility error after resize

Resolved in Pega Version 8.2.4

From within a Case and on a screen displaying the Information and Audit tabs in a Layout group, it was possible to use a series of sequences that included resizing the browser and opening Audit to cause the information tab to no longer be accessible. This has been resolved by setting the transform value to 0 after completing the resize.

SR-D92352 · Issue 553615

Completed onChange will reset FileInput value to null

Resolved in Pega Version 8.3.3

When attaching a file using the "Select File" button, it was not possible to attach the same file after deleting it. Re-attaching the file worked as expected when using Drag and Drop. Investigation showed that the onchange event occurred only when the value of an element was changed, so in this case trying to attach the same file did not change the value of the element and did not fire the onchange. To resolve this, the value of FileInput in pzMultiFilePath Control will be set to null at the end of the onChange event so that an onChange event will be triggered next time even if the same file is added.

SR-D73536 · Issue 538401

FetchApplicationLogo modified to Filter by rule resolution

Resolved in Pega Version 8.3.3

It was observed that the Report Definition rule "pzFetchApplicationLogo", referenced by Activity rule "pzLoadApplicationLogo", always returned the older version of the Binary File "webwb • pyapp-logo • svg" because it had been set to retrieve a maximum of one record and in this case the results were sorted in an order where the oldest record was at the top. As the Report Definition did not indicate any sorting, most DBMS were returning the results in no particular or predictable order. To resolve this, "Filter by rule resolution" has now been enabled for Report Definition pzFetchApplicationLogo.

SR-D84480 · Issue 546187

FilterHistory decision tree used for audit log status

Resolved in Pega Version 8.3.3

Attempting to use the “FilterHistory” decision tree in the work class to return value “false” for “pyCloseOpenAssignmentsOnResolution” to hide the “pyCloseOpenAssignmentsOnResolution” field value (“Unfinished assignments were cleaned up by the system after the completion.. ”) from history was not working as expected, and still returned the audit message. This was due to the system setting this AuditNote parameter within the “pzProcessResolutionStage” activity, where Param.UpdateHistory was set to true always. In order to support more flexibility, the Param.updateHistory paramter in step3 of the pzProcessResolutionStage activity will be set based on the FilterHistory decision tree. When set to false in FilterHistory decision tree, pyCloseOpenAssignmentsOnResolution will be set as false and audit will not be logged.

SR-D90528 · Issue 550665

Localization added to File upload alerts

Resolved in Pega Version 8.3.3

When uploading files as part of adding attachments, error and warning messages were displayed as alerts in English despite using localization. This was traced to the pzMultiDragDropControlStandard control rule having the HTML alert messages hard coded instead of using field values which could be localized. To resolve this, field values have been created for the messages related to DragDropMaxSize, FileNotExistMessage, FileUploadSupportMessage, and UnableToLoadFileMessage.