INC-183751 · Issue 665892

Improved text contrast for Attach Content button

Resolved in Pega Version 8.6.2

In order to improve accessibility, the contrast between text and background colors has been increased for the Attach Content button by updating pzMultiDragDropControlStandard to change the color from gray to black in function pzInitHTML5DD().

INC-184271 · Issue 668412

Portal Header persists appropriately

Resolved in Pega Version 8.6.2

The Portal header was disappearing immediately after case attachments were opened from the right sidebar and did not reappear even after refresh. This was traced to the absence of pd(event), and has been resolved by adding pd(event) to the onclick attribute in the anchor tag in the attachment UIKit rules.

INC-184300 · Issue 666156

Deprecated status removed from StartCaseType

Resolved in Pega Version 8.6.2

After updating from Pega v8.4 to v8.6, guardrail warnings were seen for the deprecated pxStartCaseType flow rule. This occurred for old case types created prior to v8.5. A utility has already been provided to upgrade the case type to include create stage, but this warning has been resolved by removing the deprecated status on pxStartCaseType to allow processes to proceed without a guardrail warning.

INC-186654 · Issue 669114

GetStatusChanges performance improvements

Resolved in Pega Version 8.6.2

Performance issues were seen when running the GetStatusChanges report. This was traced to the filtering methods used, and has been resolved by updating the report definition and enhancing the filtering conditions.

INC-188469 · Issue 714844

Updated retainLock for DoClose activity

Resolved in Pega Version 8.6.5

After sending an external email notification from a case, attempting to use the "close" button resulted in an access denied error. This was traced to a missed use case for recent security improvements which resulted in not setting the required parameter retainLock for the DoClose activity, and has been resolved.

INC-208394 · Issue 713554

Error handling updated for Data-Work-Attach-File

Resolved in Pega Version 8.6.5

If a file is uploaded which has the same name as an existing case attachment or if any issue happens during file attachment, the attachment will fail and an error message is displayed with an option to cancel the operation. However, even if the upload was not successful the related Data-WorkAttach-File instance was created and persisted in the Workattach table. Investigation showed this was caused by the process for persisting the Data-WorkAttach-File record occurring prior to the process that returns the errors, and this has been resolved.

INC-209404 · Issue 710406

MultiFilePath supports file upload with leading special character

Resolved in Pega Version 8.6.5

Updates have been made to the pzMultiFilePath control in order to support uploading a file with a special character such as "%" at the beginning of the name.

INC-210787 · Issue 710393

Multiple child case assignments open correctly in Ajax container

Resolved in Pega Version 8.6.5

After configuring two cases with a parent-child relationship, the child case was configured with a parallel process with two assignments. When trying to open the child case assignments in an Ajax container, only the first assignment would open. Investigation showed this was caused by the "reloadAlways" parameter not being sent to openAssignment due to a custom control being used. To resolve this, the reloadAlways has been added as an argument to the OpenAssignment function call in pyAssignmentsLabel.

INC-213654 · Issue 726002

Logic added to skip FLAudit class during compliance check

Resolved in Pega Version 8.6.5

An application compliance error was seen related to classes starting with FLAudit, which are created as part of field level audit history for the classgroup validation. This has been resolved by adding an extra condition to the Rule-Obj-Class-.Validate activity to check if inheritance is from "FLAudit-" class, and if so to skip them as their purpose is similar to History- classes which are ignored for the class group validation.

INC-215354 · Issue 712665

Data- flow actions working in Bulk Process

Resolved in Pega Version 8.6.5

When trying to render a flow action whose 'applies to' class was inherited from Data-, an error was generated indicating that the flow action could not be found. This was traced to non Work- flow actions not being correctly populated, and was an inadvertent side effect of work done to set class for inheritance if Work- is not present. This has been resolved by updating the pzPreBulkProcessModal activity to set the TempWorkPage class to Work- only if .pyActionName is pyTransferAssignment.