INC-202562 · Issue 701629
Updated FieldLevelAuditing logic for page comparison
Resolved in Pega Version 8.5.6
Optimistic locking was resulting in orphan assignments and the error "Error: Flow Not At Task, Error: Flow Removed". In addition, Get Next Work was causing duplicate Field Level Auditing records. This was traced to a missed use case in the logic used in pxFieldLevelAuditing where previousPage and PrimaryPage are compared to see whether they are equal or not, and has been resolved by adding one more condition to mark previousPage as null when the update date time or commit date time are not updated as part of processing.
INC-202943 · Issue 700195
WorkLink URL generation updated for security
Resolved in Pega Version 8.5.6
When using a WorkLink in an email, clicking the link and entering credentials on the login screen resulted in a 403 unauthorized error. This was due to a WorkLink URL generation issue caused by the non-encryption of the RedirectAndRun activity call in the URL, and has been resolved.
INC-204676 · Issue 699111
Localization added to subject line for SendEmailToAssigneeOnGoalTime
Resolved in Pega Version 8.5.6
When a Callback case was created and the assignee notified by email, the subject line was not localized. This has been corrected.
INC-207218 · Issue 706370
Check added to prevent duplicate approval by single agent
Resolved in Pega Version 8.5.6
When using a cascading Approvals process supported both by a web access button or by responding via email, a single agent could use both methods and advance a case an additional step as if they were the next approval level. This was due to the system only checking the pzInsKey when processing the approval while the assignment key will be the same for the cascading approvals assignments. This has been resolved by introducing a datetime check to validate if the email approval assignment creation datetime and the one in the database have same value; if yes the approval process will proceed and if not it will exit.
INC-188469 · Issue 714844
Updated retainLock for DoClose activity
Resolved in Pega Version 8.6.5
After sending an external email notification from a case, attempting to use the "close" button resulted in an access denied error. This was traced to a missed use case for recent security improvements which resulted in not setting the required parameter retainLock for the DoClose activity, and has been resolved.
INC-208394 · Issue 713554
Error handling updated for Data-Work-Attach-File
Resolved in Pega Version 8.6.5
If a file is uploaded which has the same name as an existing case attachment or if any issue happens during file attachment, the attachment will fail and an error message is displayed with an option to cancel the operation. However, even if the upload was not successful the related Data-WorkAttach-File instance was created and persisted in the Workattach table. Investigation showed this was caused by the process for persisting the Data-WorkAttach-File record occurring prior to the process that returns the errors, and this has been resolved.
INC-209404 · Issue 710406
MultiFilePath supports file upload with leading special character
Resolved in Pega Version 8.6.5
Updates have been made to the pzMultiFilePath control in order to support uploading a file with a special character such as "%" at the beginning of the name.
INC-210787 · Issue 710393
Multiple child case assignments open correctly in Ajax container
Resolved in Pega Version 8.6.5
After configuring two cases with a parent-child relationship, the child case was configured with a parallel process with two assignments. When trying to open the child case assignments in an Ajax container, only the first assignment would open. Investigation showed this was caused by the "reloadAlways" parameter not being sent to openAssignment due to a custom control being used. To resolve this, the reloadAlways has been added as an argument to the OpenAssignment function call in pyAssignmentsLabel.
INC-213654 · Issue 726002
Logic added to skip FLAudit class during compliance check
Resolved in Pega Version 8.6.5
An application compliance error was seen related to classes starting with FLAudit, which are created as part of field level audit history for the classgroup validation. This has been resolved by adding an extra condition to the Rule-Obj-Class-.Validate activity to check if inheritance is from "FLAudit-" class, and if so to skip them as their purpose is similar to History- classes which are ignored for the class group validation.
INC-215354 · Issue 712665
Data- flow actions working in Bulk Process
Resolved in Pega Version 8.6.5
When trying to render a flow action whose 'applies to' class was inherited from Data-, an error was generated indicating that the flow action could not be found. This was traced to non Work- flow actions not being correctly populated, and was an inadvertent side effect of work done to set class for inheritance if Work- is not present. This has been resolved by updating the pzPreBulkProcessModal activity to set the TempWorkPage class to Work- only if .pyActionName is pyTransferAssignment.