INC-184271 · Issue 668412
Portal Header persists appropriately
Resolved in Pega Version 8.6.2
The Portal header was disappearing immediately after case attachments were opened from the right sidebar and did not reappear even after refresh. This was traced to the absence of pd(event), and has been resolved by adding pd(event) to the onclick attribute in the anchor tag in the attachment UIKit rules.
INC-184300 · Issue 666156
Deprecated status removed from StartCaseType
Resolved in Pega Version 8.6.2
After updating from Pega v8.4 to v8.6, guardrail warnings were seen for the deprecated pxStartCaseType flow rule. This occurred for old case types created prior to v8.5. A utility has already been provided to upgrade the case type to include create stage, but this warning has been resolved by removing the deprecated status on pxStartCaseType to allow processes to proceed without a guardrail warning.
INC-186654 · Issue 669114
GetStatusChanges performance improvements
Resolved in Pega Version 8.6.2
Performance issues were seen when running the GetStatusChanges report. This was traced to the filtering methods used, and has been resolved by updating the report definition and enhancing the filtering conditions.