SR-B69406 · Issue 325269

GetLinkedSpecsForRule will preserve existing framework rule spec links

Resolved in Pega Version 7.3.1

When a framework layer rule was opened Specs were not listed, and checking out and checking in the rule caused the link to spec which was associated in the framework layer to also be deleted. This appeared as specifications created for the FW layer not being visible from the Rule form when the current access group pointed into the Implementation layer. It should be noted that the Framework layer specs cannot be linked with framework layer rules when doing development in the implementation layer - that is an expected behavior. Therefore the fix for this issue will just retain the existing rule specification links even for framework rules: On Report definition pzGetLinkedSpecsForRule context mode was changed to All Rules in Application and Frameworks except PegaRULES. PostCheckOut activity in following classes were updated to call PostCheckOut from Rule- Rule-HTML-Section Rule-HTML-Harness Rule-File-Stencil Rule-File-

SR-B77272 · Issue 326822

TransformerFactory security functions reverted

Resolved in Pega Version 7.3.1

Export to Excel was broken in the IBM environment. This was related to compatibility with security updates which were not consistently implemented by TransformerFactory installations. To resolve this condition, those security changes have been removed from the following functions: DCOdocumentToBytes DCOnodeToString DCOgetStringFromDocument

SR-B77713 · Issue 327047

Null check added to pxSystemFlow to handle post-upgrade assignment display

Resolved in Pega Version 7.3.1

After upgrade, assignments were not being displayed. This was due to pxSystemFlow being blank in earlier versions of Pega. In the Flows section the assignments are filtered based on false check, hence assignments were not seen. To prevent this issue, a null check has been added.

SR-B77745 · Issue 327019

pyCaseBreadCrumb control localized

Resolved in Pega Version 7.3.1

When viewing a case, the pyCaseBreadCrumb control was not localizing the value, instead always displaying the value of pyLabel. This has been corrected.

SR-B64309 · Issue 315889

PDN help properly reflects FlowAnalysis implementation in the Diagram tab

Resolved in Pega Version 7.3.1

The documentation has been updated in the PDN to reflect that the ruleform "Flow Analysis" option is no longer available. The references to this were mistakenly left visible due to a build issue and the help files have now been republished so they match the current implementation of the Flow Analysis option, which is available on the Diagram tab.

SR-D22415 · Issue 493439

Enhancement added to expose BrowserAttachmentTypeTable

Resolved in Pega Version 8.3.1

By default, the inline view of PDF files appears with the thread name visible. An enhancement has been made to expose pzBrowserAttachmentTypeTable as a py rule: when the DT is overridden such that return is false for PDF, the inline view is not displayed but instead the PDF is downloaded when clicked.

SR-D23723 · Issue 503087

pxGenerateExcelFile updated for handling blank dates

Resolved in Pega Version 8.3.1

When using a custom template for exporting to Excel, blank DateTime property column values defaulted to the current date. To resolve this, the pxGenerateExcelFile activity has been updated to ensure that an empty date will be exported as blank and that given dates will appear in the correct datetime format.

SR-D26589 · Issue 496719

pxParseExcelFile activity will now parse multiple sheets

Resolved in Pega Version 8.3.1

When trying to use the activity pxParseExcelFile on an Excel file containing three sheets where each sheet had a different pagelist, the properties mentioned in sheet 1 were populated on upload but the remaining sheets only showed the error message "Could not get clipboard property for reference Work Queues.". This was caused by an error in Row index handling for the additional sheets, and has been resolved by updating the logic to populate the data in the clipboard. Additional issues for this issue in 8.4 to fix issues like formulae not getting evaluated and $ not parsed: 501592, 501383

SR-D29114 · Issue 499930

Added handling for bulleted text insert triggering audit

Resolved in Pega Version 8.3.1

When a bulleted text (copied from an email or rich text ) was used in the text area property, the audit considered it as a change even when there was no change. This was tracked to the field value 'pyHistoryMemo • ChangeTrack_Add' in @baseclass which is being used to get the localized value for audit memo: the field value accepts only 2 parameters, but the inserted text area input contained the '\t' that is used for parameter translation. To resolve this, the system will call the addMemoForSecurityChangeTracking utility method to replace all \t's present in both the Current Value and Previous value with 'empty' such that no '\t' characters are available in either of the string parameters.

SR-D37444 · Issue 507037

WorkBasketGadget control updated for improved backwards compatibility

Resolved in Pega Version 8.3.1

After upgrade, the WorkBasketGadget Control was not retrieving the work queues. This was traced to a backwards compatibility issue introduced when greater security was put in place. The control WorkBasketGadget contains a call to pzEncryptURLActionString that was introduced in 8.x versions of the platform to encrypt URLs to avoid hijacking. The content of the URL relies on the pxRequestor.pxWorkGroup property, which is resolved using pega:reference tags. This approach was working in versions below 8.x, but these tags were not resolved at runtime. To correct this, requestorWorkGroup will be resolved as string and passed as a parameter instead of using pega:reference tags.