SR-D42670 · Issue 510182
Force order added to inner join when running a Rules Resolution filter
Resolved in Pega Version 8.3.1
After upgrade, D_getResolvedWorkStatuses was not loading properly due to a Report Definition that used a Filter by Rule Resolution option timing out on the SQL Server. When the Filter by Rule Resolution option is selected in RD, it will generate a rule resolution query with an inner join which can cause a time out on the SQL Server while it tries to find out the join order for tables with multiple joins. To resolve this, the SQL server will provide a Force order, merge inner join hint option by way of an added DSS reporting/useForceOrderHint. Additionally, reporting/useMergeHintForRRquery should be set on Pega-Reporting to set things up for using the Merge Inner join hint in the query.
SR-D16200 · Issue 494582
Support added for decimal values in RichTextDisplay HTML
Resolved in Pega Version 8.3.1
After upgrade, correspondence in Outlook was displayed with an incorrect left alignment, and footer images were stuck together. This was caused by a difference in the Richtextdisplay mode, which was previously set to 'literal' and is now richtextdisplay.Issue. To resolve this, an enhancement has been added which supports decimal values for the HTML attributes.
SR-D16433 · Issue 499294
Exception handling added for upgraded custom decision tables
Resolved in Pega Version 8.3.1
After upgrade, the status fail message "There has been an issue; please consult your system administrator" appeared with a blue screen in the Run window when attempting to run a Decision table from Actions-> Run option. This impacted the ability to create unit test cases. Analysis showed the issue occurred for any decision table where "Evaluate All rows" was enabled and list properties were used in Actions if there was no value for the list property after the execution of decision table. This was traced to a NullPointerException in a RunRuleFromPage activity in a customized in PUnit ruleset, and was caused by having list properties in the actions of a decision table that had not been populated during rule execution. Exception handling has been added to resolve this.
SR-D32086 · Issue 500893
Memory leak repaired
Resolved in Pega Version 8.3.1
A server side memory leak was traced to heap utilization increasing due to a Stream control assembly problem where the CleanForReuse() function was not cleaning up pzAuto. The cleanForReuse method in generated HTML properties is used to either initialize local fields, in which case aContext will be non-null, or to clear the object for pooling, in which case aContext will be null. Because the pzAuto variable was not being properly nullified, pooled controls were retaining stale references to StreamTools, LayoutRuntime, PRThread, and others. This has been resolved by adding code to ensure the pzAuto variable is correctly nullified, and additional work has been done to improve memory management.
SR-D18036 · Issue 495396
Holdability flag set on connection for using MS SQL in Designer Studio
Resolved in Pega Version 8.3.1
Static assembler was not working from Designer Studio, displaying the error "com.microsoft.sqlserver.jdbc.SQLServerException: SQL Server supports holdability at the connection level only. Use the connection.setHoldability() method." Investigation showed that ApplicationAssembly.getResultSetForQuery explicitly sets the holdability flag on the prepared statement, and this issue has been resolved by updating the system to set the holdability flag on connection as well.
SR-C80200 · Issue 494446
Resolved Sporadic ControlBuild error in sections
Resolved in Pega Version 8.3.1
After upgrade, a sporadic error was seen with sections of a VTable after a server restart where a portion would not load and the error "com.pegarules.generated.html_property.ra_stream_pxtextinput_1786000787_default incompatible with com.pega.pegarules.pub.runtime.ControlBuilder" was seen. This issue was traced to invalid generation of an assembly parameter map for random sections the first time the table was called after restart. To resolve this, the system will now allow assembly parameter generation for a second time when they are empty, and the assembly parameters preparation will be handled as a synchronous process.
SR-D13514 · Issue 489433
Data-test-id handling updated to resolve testing issue with custom controls
Resolved in Pega Version 8.3.1
After configuring a custom control, the control did not render as expected when trying to capture the scenario testing. Investigation showed that in read-only mode, two spans were wrapped with same data-test-id when formatType is number. This caused a ‘no unique selector’ issue with scenario tests. To resolve this, pzpega_ui_template_displayText.js has been updated to not include data-test-id on outer span when formatType is number.
SR-D28060 · Issue 498749
Cross-site scripting filtering added to App Studio
Resolved in Pega Version 8.3.1
The pzDisplaySpaceFeedTitle control which is used to display the audit feed in Pega App Studio has been updated with cross-site scripting filtering.
SR-D28293 · Issue 498233
Pega Survey answer values support special characters
Resolved in Pega Version 8.3.1
When using a Complex radio control (RadioButtonComplexQuestionSurvey), a selected option that used answer values containing special characters was cleared on refresh. This was traced to a mismatch between strAnswer and strValue in the control logic, and has been corrected.
SR-D30428 · Issue 503424
Added handling for deprecated UI Kit in Pulse OpenURLInWindow
Resolved in Pega Version 8.3.1
After upgrade, clicking on a link in a Pulse comment opened a new window with an error message indicating no content was returned. Investigation showed that if an older deprecated version of the UI kit was used, 'Open URL in window' was configured as Run Script function. The more recent versions use an OpenURLInWindow action. To resolve this, the script has been updated to use an action and pass the correct parameters.