SR-C80200 · Issue 494446
Resolved Sporadic ControlBuild error in sections
Resolved in Pega Version 8.3.1
After upgrade, a sporadic error was seen with sections of a VTable after a server restart where a portion would not load and the error "com.pegarules.generated.html_property.ra_stream_pxtextinput_1786000787_default incompatible with com.pega.pegarules.pub.runtime.ControlBuilder" was seen. This issue was traced to invalid generation of an assembly parameter map for random sections the first time the table was called after restart. To resolve this, the system will now allow assembly parameter generation for a second time when they are empty, and the assembly parameters preparation will be handled as a synchronous process.
SR-D13514 · Issue 489433
Data-test-id handling updated to resolve testing issue with custom controls
Resolved in Pega Version 8.3.1
After configuring a custom control, the control did not render as expected when trying to capture the scenario testing. Investigation showed that in read-only mode, two spans were wrapped with same data-test-id when formatType is number. This caused a ‘no unique selector’ issue with scenario tests. To resolve this, pzpega_ui_template_displayText.js has been updated to not include data-test-id on outer span when formatType is number.