INC-175205 · Issue 652529
Agent restart made more resilient
Resolved in Pega Version 8.4.5
During a timeout outage, agents intermittently encountered a NoClassDefFound error and were disabled. After the database connection was restored, the agents were not automatically restarting. This has been resolved by making the code more resilient to errors; agent will be restarted when a temporary issue is detected, and the restart will be immune to most exceptions.
INC-179861 · Issue 658948
AES call to mbean disabled
Resolved in Pega Version 8.4.5
Under certain conditions, the AESRemote 'push memory' agent call to the legacy memory management mbean caused unexpected behavior in declarative rules for work running in data flows and queue processors. This has been resolved at this time by overriding the push memory usage agent activity to skip mbean and connect REST.
INC-180207 · Issue 659097
Corrected race condition that caused JobScheduler error
Resolved in Pega Version 8.4.5
A race condition between the pzInitializeQueueProcessors and pyPersistNodeState job schedulers that both run at platform's start was causing a null pointer exception with the error "com.pega.platform.executor.jobscheduler.scheduler.JobExecutionException: Activity execution failed with [PRRuntimeException]". This has been resolved by moving the QueueProcessor initialization process from JobScheduler to StartupTask.
SR-D48369 · Issue 514307
Reinitializing Full Text Search will shut down Elastic Search regardless of search initialization status
Resolved in Pega Version 8.1.8
Pega search was only sporadically working after converting from standard sandbox-marketing to largesandbox-marketing. This was traced to the Full-Text Search initialization having failed on the app-tier node during re-initialization. As part of re-initialization, the existing node is shut down and the Elastic Search node is started. The shutdown process relied on a boolean flag which indicated if the current status of full-text search initialization was successful. In this case, ES was trying to validate all the cluster level settings, for every save of one of the cluster level settings, but could not due to topology changes in the Util Tier node. The boolean flag indicated initialization had failed so the shutdown process was not invoked, yet the system was attempting to start the second instance of an ES node on the same machine. To resolve this, the shutdown FTS code has been modified to shutdown ES regardless of the search initialization status.
SR-D56293 · Issue 536776
Resolved timeout errors related to getIndexInfo
Resolved in Pega Version 8.1.8
When attempting to import large files (around 300MB) via Designer Studio a time out error was seen, but the same upload worked as expected from the command line. Investigation showed that the "approximate" argument in getIndexInfo caused wasteful analytic operations to be run on the database, hampering performance. To resolve this, areas where the results of the analysis are not needed have been modified to have aApproximate set to be true so it will not be run.
SR-D60375 · Issue 527755
Resolved upgrade SqlSyntaxErrorException
Resolved in Pega Version 8.1.8
When trying to perform an in-place update, the error "SqlSyntaxErrorException" appeared. Investigation showed that DDL statements for Adding 'pzInsKey' as PrimaryKey for Tables pc_work and pr_sys_locks were generated during the upgrade while pzInsKey was already the PrimaryKey in corresponding tables. This has been corrected.
SR-D65112 · Issue 541147
Added support for imported rules to populate bixreportpage
Resolved in Pega Version 8.1.8
Extract rules were not holding the filter criteria after upgrade while performing save-as (for the first time) of the imported rules from the previous version. Criteria were held when the filters were created in the new version. This was caused by BIX extracts created in earlier releases (7.x) not having bixreportpage included. When an environment was upgraded to 8.x versions, opening an extract required the bixreportpage to be populated with Report Definition metadata including the filters defined in the actual extract. Although the filters from the original extract were converted to filters that are acceptable by ReportDefinition, they were not being added to bixreportpage on opening the extract. To resolve this, the system has been updated to copy the filters back to bixreportpage on opening the extract in the upgraded environment.
SR-D66986 · Issue 539412
BIX command line support improved
Resolved in Pega Version 8.1.8
Post-upgrade, it was seen that changes to the engine which validate that Data-Admin-DB-Name is not defined multiple times caused the BIX command line extracts to no longer work the same way. In order to improve backwards compatibility, updates have been made to loosen the validation in JdbcConfigurationFactory to always prefer prconfig settings if there are multiple definitions.
SR-D71977 · Issue 535600
Obj-Browse will retrieve more than 50 records
Resolved in Pega Version 8.1.8
After performing multiple skims, a newly added property was not retrieved when an Obj-Browse was performed. In Obj-Browse action, when a class is mapped to an external table and does not contain BLOB column pzpvstream, in a specific case where pxObjClass value is a reference to a parameter, a list of properties mapped to the class explicitly by querying pr4_rule_property table using NativeSQL is fetched. This call by default returns only 50 records: in cases where there are more than 50 properties for an external class, some of the properties from the obj-browse response mapping are therefore missed. To resolve this, the limit of 50 records has been removed from this NativeSQL call.
SR-D79565 · Issue 541532
BIX extracts traverse up from embedded pages to find target tables
Resolved in Pega Version 8.1.8
For BIX Extracts with Output Format : Database Schema, the target table name was not being generated if the properties were buried under two levels of Embedded Pages. Instead, in case of multiple nested levels of PAGE property types, the system ended up referring the immediate Parent page or its parent PAGE for pySourceName. Since this is of type PAGE, an empty value was returned for the target table name and the extract would fail. To resolve this, the system has been updated to traverse up the node parents until the correct target table name is found.