Skip to main content

Resolved Issues

View the resolved issues for a specific Platform release.

Go to download resolved issues by patch release.

Browse release notes for a selected Pega Version.

NOTE: Enter just the Case ID number (SR or INC) in order to find the associated Support Request.

Please note: beginning with the Pega Platform 8.7.4 Patch, the Resolved Issues have moved to the Support Center.

SR-D75649 · Issue 547565

OrgChartWorkGroup update issue resolved

Resolved in Pega Version 8.1.8

The instances of Index-PegaFS-Data-OrgChartWorkGroup table were corrupted after adding a new department via the landing page. This was traced to the missed scenario of a Page-Copy with declare index present in it, and has been resolved.

SR-D84880 · Issue 546890

Null check added to resolve addmapcasetomap error

Resolved in Pega Version 8.1.8

Using a createcase flow shape to create child cases by looping on a page list on the parent case resulted in pzaddmapcasetomap throwing an exception related to the activity pzLoadCaseHierarchyWrapper in step 5. This was traced to a page being removed after the list of pages was received in findPageByHandle, and has been resolved by adding a null check.

SR-D62755 · Issue 522827

Enhanced diagnostic logging for Email Listener failures

Resolved in Pega Version 8.1.8

In order to better diagnose issues where the email listener entered a disabled state as soon as it was started, a catch block has been added to enhance logging the reason of failure

SR-D64558 · Issue 527676

AttachmentContent supports S3 storage

Resolved in Pega Version 8.1.8

Using a D_AttachmentContent data page to display the contents of an attachment by way of the pyGetAttachmentContent activity worked when using the Pega database for storage, but generated an error stating CMIS access was disabled after switching to S3 storage. This was traced to restrictions on Link-Attachment pages in Step 2, Line 64 of pyGetAttachmentContent to enable attachment stream retrieval from web storage and repositories by D_AttachmentContent, which has now been removed. In addition, pyGetAttachmentContent has been updated to behave the same whether a Link-Attachment page or Data-WorkAttach page is provided when populateAttachStream is set to false, and the rule documentation (description/usage) has been updated accordingly.

SR-D71669 · Issue 540099

Logic trimmed for better Listener performance

Resolved in Pega Version 8.1.8

After multiple email listeners with Data indexing were enabled, the FTSIndexer queue was filling with Email Listener instances. Investigation showed that although Listener Management has logic for updating the last access time of all listeners by using APIs, the Email Listener was explicitly opening the email listener rule to update the last access time every time it was run. This has been corrected.

SR-D76291 · Issue 541013

Check added for Repositories before saving attachment

Resolved in Pega Version 8.1.8

When creating or updating a case through email listener, the Link-Attachment defaulted the pxStorageType to 'WebStorage'. This caused an issue when using PegaS3, which needs pxStorageType 'Repository'. To resolve this, a check has been added to see if Repositories are enabled, and if they are the storageType will be set accordingly.

INC-158018 · Issue 633374

Archiving updated to include pxobjclass in CTE column list

Resolved in Pega Version 8.5.5

After enabling the case archival feature on a casetype, cases were getting stuck in the Archive-Ready state while being archived, and a 'column not found' error was seen. Investigation showed that the generated SQL statement used to retrieve the resolved case instances used a common table expression (CTE) whose columns were inskey, insclass, and parentinskey, and the query that referenced the CTE was attempting to compare the column pxobjclass when pxobjclass did not exist in the CTE's column list. To resolve this, the CTE column list has been updated to pzinskey, pxobjclass, and parentinskey to prevent the 'column not found error' from occurring, and the query that referenced the CTE was also updated to use the correct column names and aliases.

INC-159244 · Issue 627864

Bulk actions check in preserves declare expression legacy setting

Resolved in Pega Version 8.5.5

When a declare expression was saved in legacy mode with "Whenever used" selected in change tracking, performing a bulk check-in of the rule caused the expression to default to the new forward chaining method. This did not occur when using a direct check-in. Investigation showed this was caused by the check-in page holding a legacy value before the step execution, and has been resolved by adding a pre-save activity before the validation activity that will restore the .pyIsLegacy value from .pyExpressionTypeSelector, if set.

INC-162262 · Issue 654964

Query added to find time zone for MSSQL database

Resolved in Pega Version 8.5.5

The exception "com.microsoft.sqlserver.jdbc.SQLServerException: xp_regread() returned error 5, 'Access is denied.'" was generated when the AES agent PushDBSizeInfo was being run. This was traced to the GetDBInfo activity trying to retrieve the time zone of the MSSQL database by executing a query that used a Microsoft SQL routine to read the windows registry to get the current time zone. The error was not due to security within the SQL Server, but instead was caused by Microsoft Windows security related to the permissions on the registry keys for the users under which specific SQL Server processes were running. To resolve this, an update has been made to call a different query which will get the time zone for the SQL Server.

INC-162262 · Issue 658949

AES call to mbean disabled

Resolved in Pega Version 8.5.5

Under certain conditions, the AESRemote 'push memory' agent call to the legacy memory management mbean caused unexpected behavior in declarative rules for work running in data flows and queue processors. This has been resolved at this time by overriding the push memory usage agent activity to skip mbean and connect REST.

We'd prefer it if you saw us at our best.

Pega.com is not optimized for Internet Explorer. For the optimal experience, please use:

Close Deprecation Notice
Contact us