SR-B6971 · Issue 285310
Error propagation corrected for RDB-Save with RunInParallel
Resolved in Pega Version 7.3
If several Connect SQLs were called via the RDB-Save activity method with RunInParallel selected, failure of one of the Connect SQLs was not being caught and no errors were captured. This was traced to a situation where an exception thrown at the childcase with this combination of settings was propagated to the parent, and has been corrected by adding a Data-Admin-System-Setting "isPropagateExceptionFromChildToParent" defined in "Pega-RULES" ruleset, which has a default value of "true" only for RDB-Save method (not for all RDB-methods).
SR-B6971 · Issue 279537
Error propagation corrected for RDB-Save with RunInParallel
Resolved in Pega Version 7.3
If several Connect SQLs were called via the RDB-Save activity method with RunInParallel selected, failure of one of the Connect SQLs was not being caught and no errors were captured. This was traced to a situation where an exception thrown at the childcase with this combination of settings was propagated to the parent, and has been corrected by adding a Data-Admin-System-Setting "isPropagateExceptionFromChildToParent" defined in "Pega-RULES" ruleset, which has a default value of "true" only for RDB-Save method (not for all RDB-methods).
SR-B6980 · Issue 278169
fixed naming in multiple extracts run from the command line
Resolved in Pega Version 7.3
When running multiple comma separated extracts at a time using command lineoption -i, all of the rules in the manifest file contained the value of the last extract name only. This was a missed use case, and ExtractImpl has been modified to correct it.
SR-B7225 · Issue 277783
BIX documentation updated for Extract Rules
Resolved in Pega Version 7.3
The documentation outlining best practices for using BIX has been updated to reflect that when extractions are being run asynchronously there must be enough threads for each of the concurrently running extractions. The section "Running an Extract rule using a Pega 7 Platform agent" has been updated to read: "Number of concurrent extracts scheduled has to be limited based on the prconfig "agent/threadpoolsize." Set the prconfig setting agent/threadpoolsize to the max number of concurrent extractions you will be executing. The default value for this setting is 5 and the maximum value is 10.
SR-B7620 · Issue 289885
PopulateCaseContents activity updated
Resolved in Pega Version 7.3
The PopulateCaseContents activity has been updated to better handle missing or empty properties to ensure the flow name and RefObjectClass values are populated properly.
SR-B7620 · Issue 289885
PopulateCaseContents activity updated
Resolved in Pega Version 7.3
The PopulateCaseContents activity has been updated to better handle missing or empty properties to ensure the flow name and RefObjectClass values are populated properly.
SR-B7942 · Issue 284735
PDF barcode generation from eForm given configurable parameter checkbox
Resolved in Pega Version 7.3
When generating a PDF file based on an eForm that contains barcodes displayed via base64 encoded images, making the file read-only by using ConcatenateEForm's PerformFieldFlattening option prevented the barcodes from displaying. This was due to an "append" flag being passed to the 3rd party iText Library API "PdfStamper", and has been resolved with the addition of a flag (EnableNewVersion) in the "GenerateEForm" activity. The parameter will be by default true and may be unchecked for false, and is accompanied by a tool tip on hover of the checkbox as well as iText help.
SR-B7942 · Issue 285735
PDF barcode generation from eForm given configurable parameter checkbox
Resolved in Pega Version 7.3
When generating a PDF file based on an eForm that contains barcodes displayed via base64 encoded images, making the file read-only by using ConcatenateEForm's PerformFieldFlattening option prevented the barcodes from displaying. This was due to an "append" flag being passed to the 3rd party iText Library API "PdfStamper", and has been resolved with the addition of a flag (EnableNewVersion) in the "GenerateEForm" activity. The parameter will be by default true and may be unchecked for false, and is accompanied by a tool tip on hover of the checkbox as well as iText help.
SR-B8478 · Issue 278805
ExtractSection data transform optimized
Resolved in Pega Version 7.3
The code in pzExtractSectionPostDT and pzExtractSectionPostActivity has been optimized to improve data transform processing time.
SR-B7729 · Issue 277669
Resolved file upload error for locales with special language characters
Resolved in Pega Version 7.3
Uploads to Pulse were failing when the file names or file paths contained special Turkish characters. This was an issue with the conversion to lower case changing the length of the string for some locale packages and has been resolved by swapping the call to string.toLowerCase for a call to StringUtils.indexOfIgnoreCase.