SR-D32086 · Issue 500893
Memory leak repaired
Resolved in Pega Version 8.3.1
A server side memory leak was traced to heap utilization increasing due to a Stream control assembly problem where the CleanForReuse() function was not cleaning up pzAuto. The cleanForReuse method in generated HTML properties is used to either initialize local fields, in which case aContext will be non-null, or to clear the object for pooling, in which case aContext will be null. Because the pzAuto variable was not being properly nullified, pooled controls were retaining stale references to StreamTools, LayoutRuntime, PRThread, and others. This has been resolved by adding code to ensure the pzAuto variable is correctly nullified, and additional work has been done to improve memory management.
SR-D18036 · Issue 495396
Holdability flag set on connection for using MS SQL in Designer Studio
Resolved in Pega Version 8.3.1
Static assembler was not working from Designer Studio, displaying the error "com.microsoft.sqlserver.jdbc.SQLServerException: SQL Server supports holdability at the connection level only. Use the connection.setHoldability() method." Investigation showed that ApplicationAssembly.getResultSetForQuery explicitly sets the holdability flag on the prepared statement, and this issue has been resolved by updating the system to set the holdability flag on connection as well.
SR-C80200 · Issue 494446
Resolved Sporadic ControlBuild error in sections
Resolved in Pega Version 8.3.1
After upgrade, a sporadic error was seen with sections of a VTable after a server restart where a portion would not load and the error "com.pegarules.generated.html_property.ra_stream_pxtextinput_1786000787_default incompatible with com.pega.pegarules.pub.runtime.ControlBuilder" was seen. This issue was traced to invalid generation of an assembly parameter map for random sections the first time the table was called after restart. To resolve this, the system will now allow assembly parameter generation for a second time when they are empty, and the assembly parameters preparation will be handled as a synchronous process.
SR-D13514 · Issue 489433
Data-test-id handling updated to resolve testing issue with custom controls
Resolved in Pega Version 8.3.1
After configuring a custom control, the control did not render as expected when trying to capture the scenario testing. Investigation showed that in read-only mode, two spans were wrapped with same data-test-id when formatType is number. This caused a ‘no unique selector’ issue with scenario tests. To resolve this, pzpega_ui_template_displayText.js has been updated to not include data-test-id on outer span when formatType is number.