INC-143320 · Issue 602281

Support added for email addresses with hyphen in domain name

Resolved in Pega Version 8.3.5

When attempting to enter a email with a hyphen '-' in the domain part of an email ID ([email protected]), the reply button was getting disabled. This was caused by the regex validation implemented in the "pzValidateEmailAddress" (Work-Channel-Triage-Email) standard activity not covering all the possible cases. To resolve this, regex has been changed to instead use a platform-provided rule to ValidateEmailAddress.

INC-141579 · Issue 591852

Enhancement added for node heartbeat recovery process

Resolved in Pega Version 8.3.5

Nodes were not showing up in the admin portal even though they were up and running and could be seen in the pr_sys_statusnodes table. The exception "An exception was encountered while invoking the cluster membership listener callback" was seen. All nodes became visible again after multiple restarts. The root cause was traced back to a temporary database connectivity problem. The database itself was fine according to database monitoring reports, but a network problem, a slow database query, or another issue prevented Pega from establishing a connection for more than a minute. An enhancement has been made to resolve this: if a node becomes unhealthy due to the service registry missing due to a failed heartbeat, the heartbeat will try to recover after 60 seconds and keep trying every 30 seconds until it succeeds.

INC-142674 · Issue 594496

Enhancement added for node heartbeat recovery process

Resolved in Pega Version 8.3.5

Nodes were not showing up in the admin portal even though they were up and running and could be seen in the pr_sys_statusnodes table. The exception "An exception was encountered while invoking the cluster membership listener callback" was seen. All nodes became visible again after multiple restarts. The root cause was traced back to a temporary database connectivity problem. The database itself was fine according to database monitoring reports, but a network problem, a slow database query, or another issue prevented Pega from establishing a connection for more than a minute. An enhancement has been made to resolve this: if a node becomes unhealthy due to the service registry missing due to a failed heartbeat, the heartbeat will try to recover after 60 seconds and keep trying every 30 seconds until it succeeds.

INC-137255 · Issue 584910

Resolved Cassandra query read/write latency

Resolved in Pega Version 8.3.5

Read/write latency was seen when certain Cassandra queries were triggered by the system. This was traced to an unusual case where a flush was not done for an exceptionally long time period, and has been resolved.

INC-159836 · Issue 631206

Upgraded Apache UIMA Ruta libraries to resolve memory leak

Resolved in Pega Version 8.6.2

A memory leak issue that resulted in a reboot being needed every few days was traced to the class org.apache.uima.ruta.rule.RuleMatch. This has been resolved by upgrading the Apache UIMA Ruta libraries to v2.8.1.

INC-181148 · Issue 663164

Documentation updated for altering data type to Timestamp to avoid duplicate data in Decision Hub

Resolved in Pega Version 8.5.6

By default, the pxOutComeTime column has a Date data type in the pr_data_ih_fact table. This may cause duplicate data issues. To resolve this, the 8.5 and 8.6 installation and upgrade guides for Pega Customer Decision Hub have been updated to include a new procedure "Modifying column definitions to use the TIMESTAMP datatype in an Oracle database". Performing this procedure will allow users to avoid the duplicate data issue. All documents are available from the Pega Customer Decision Hub product page.

INC-175994 · Issue 667481

Removed redundant Microsoft Outlook email interaction chain

Resolved in Pega Version 8.6.2

When opening an email interaction case, the email editor user interface area showed the complete email chain of the email for every new message that came in related to the case. This was traced to the difference in the selectors that various email clients use to construct a response to an email with email history in it, and has been resolved by updating the selectors for Microsoft Outlook in pyRichTextEmailHistorySelector so no conversation is repeated when using that client.

INC-176881 · Issue 669701

Resource added to extract email threading code from message body

Resolved in Pega Version 8.6.2

In some scenarios the case ID was not being sent in the subject of email replies as expected, and the secure tracking code was part of the email body instead. That caused replies back to the email thread to create a new email interaction case instead of properly threading the new message into the conversation. Investigation traced this to some email clients removing space after the tracking code. To resolve this, an update has been made which will extract the tracking code from email-content html if it is found and otherwise fallback to the email body.

INC-178990 · Issue 664613

Added handling for reloading portal while ChatBot is active

Resolved in Pega Version 8.6.2

An issue was seen with UI rendering when a customer tried to reload the portal where the chatbot is deployed. Investigation showed that this was caused by the screen going to pyCreate harness instead of ChatPerform harness due tot he unexpected refresh, and has been resolved by updating the handling for the Chat Work page and the business case so that pyWorkPage is always Work-Channel-Chat.

INC-179888 · Issue 663845

Training data correctly added to model

Resolved in Pega Version 8.6.2

Negative training data was not getting added to the entity model. This was traced to logic used to remove consecutive spaces which was incorrectly removing new lines and leading to entity detection of entities such as address line. This logic has now been removed.