INC-126129 · Issue 569666
PropertyToColumnMap made more robust
Resolved in Pega Version 8.1.9
The DF_ProcessEmails dataflow was intermittently failing with a StageException error. This was traced to schema changes being propagated asynchronously by system pulse, which seem to have caused PropertyToColumnMap to cache stale schema. To resolve this, if the property mapping is not found the first time, the system will make a second attempt to get the mapping. Additional logging has also been added for better diagnostics.
INC-128385 · Issue 564521
Behavior made consistent between SSA and legacy engines
Resolved in Pega Version 8.1.9
There was a behavioral disparity between the legacy execution engine and the SSA engine where the latter was not creating a new page when the index was one above the size of the page list. This has now been corrected in order to make the SSA behavior fully backward compatible with the legacy engine, i.e. a new blank page will be added to the list if the index is one above the size of the list.
INC-129222 · Issue 568530
Handling improvements for commit logs
Resolved in Pega Version 8.1.9
The ADM commit log logs the number of unconsumed messages that are going to expire. In certain circumstances, it can include unconsumed messages that are not going to expire in the count. Because they are not expired and removed, the environment was running out of disk space due to the ADM commitlogs table growing larger than expected and performance issues were seen. To resolve this, a new adm_commitlog.adm_responses_commit_log_date_tiered table has been created, with a default_time_to_live of 24 hours. DateTieredCompactionStrategy has been set with max_window_size_seconds as 24hrs and tombstone_compaction_interval as 24hrs.
INC-132976 · Issue 580685
Performance improvements for Test Strategy data flow
Resolved in Pega Version 8.1.9
In the Test Strategy panel under Single case -> "Settings", selecting the "Data flow" option and choosing CustomerData dataflow was taking an excessive amount of time to run on a system with an extremely large database. To improve performance, two areas have been addressed: 1) the default behavior for record key suggestions in the test panel has been modified to collect only the ID as the additional data is not necessary at that time; 2) a DSS has been added that will opt out of reading and collecting the customer IDs in order to minimize data stored on the clipboard.
INC-138037 · Issue 586593
Strategy handling updated for very large systems using IH summary
Resolved in Pega Version 8.1.9
When a Strategy in a Real-time dataflow used IH Summary on a system with more than 5000 groups for one eventKey, the message "Error retrieving aggregates from Cassandra KVS" intermittently appeared. Investigation showed that if the number of result rows was greater than the FETCH_SIZE (set to 5000), it meant another read to Cassandra was required and an exception was generated. To resolve this, updates have been made so that instead of returning maps, the system will return iterators and change them to map on the calling thread.
SR-D92734 · Issue 553412
Simulation can take Data flow type as destination
Resolved in Pega Version 8.1.9
Support has been added for Data flow functionality as simulation target and data transform in simulation input.
INC-143121 · Issue 610732
Timeout for loading predictors made configurable
Resolved in Pega Version 8.3.6
When using an extremely large number of predictors, the Report definition pzADMPredictorsFilter was suffering timeouts due to the time for loading predictors from the database exceeding the time threshold allowed. This has been resolved by marking the rule as editable to allow custom setting of the threshold according to need.
INC-148899 · Issue 615702
Adaptive models update correctly
Resolved in Pega Version 8.3.6
Some models had the recorded responses column updated, but the models (number of Positive, Negative and Processed Responses) were not updated. Investigation showed that deleting the modelRuleConfiguration through the stateManager/client did not delete modelFactories related to the configuration. If a new configuration came in with a different algorithm, the update issue occurred. This has been resolved by reseting the configuration according to its factory in that specific case.
INC-155822 · Issue 618267
Locking added to avoid null pointer error for auto-populate property
Resolved in Pega Version 8.3.6
After configuring the auto populate property "OrgProduct" which referred to a data page, the system experiencing heavy load led to the property not getting properly initialized. This resulted in a WrongModeException and NullPointerException. To resolve this, the system has been updated to lock the requestor when Queue Processors execute their activity. This will prevent race conditions and concurrent modifications if other threads are accessing the same requestor.
INC-157629 · Issue 626633
Duplicate key exception resolved for adaptive model
Resolved in Pega Version 8.3.6
During the model snapshot update, a DuplicateKeyException was generated while trying to insert a record in to the predictor table. This did not affect the model's learning, but did appear ion the model monitoring report. This was traced to a local scenario of having the same outcome values defined on the model with different cases (Accept and accept). All predictors used in an Adaptive model are inserted into the model monitoring tables as a part of the monitoring job: because the monitoring tables are not case sensitive, this lead to a unique constraint exception since there were multiple IH predictors with the same name. To resolve this, validation has been added which will skip adding duplicates from new responses.