SR-133183 · Issue 205535
Fixed flow line distortion in Process Modeler
Resolved in Pega Version 7.1.9
When clicking through to a subprocess from a parent flow (by clicking the + sign in the blue subprocess shape), flow lines in the subprocess were shown in a distorted fashion. When opening the same flow in a separate tab (by right clicking the blue subprocess shape and selecting Open Flow) the flow lines were correctly painted. This was an issue caused by the different renderings of the flow depending on whether there was a click through to it (with the + on the parent flow?s subprocess shape), or the subflow was opened in a separate tab (with open Flow). After the Process Modeler saved and checked-in the flow, the connector lines were re-drawn in ways that were non-intuitive and hard to interpret due to the edge routing in PM being calculated off incorrect input data that was taking into account shapes that were not represented on the screen. To fix this, the system now ensures the edges are routed without taking into account any shapes not represented on the canvas.
SR-133184 · Issue 203710
Fixed flow line distortion in Process Modeler
Resolved in Pega Version 7.1.9
When clicking through to a subprocess from a parent flow (by clicking the + sign in the blue subprocess shape), flow lines in the subprocess were shown in a distorted fashion. When opening the same flow in a separate tab (by right clicking the blue subprocess shape and selecting Open Flow) the flow lines were correctly painted. This was an issue caused by the different renderings of the flow depending on whether there was a click through to it (with the + on the parent flow?s subprocess shape), or the subflow was opened in a separate tab (with open Flow). After the Process Modeler saved and checked-in the flow, the connector lines were re-drawn in ways that were non-intuitive and hard to interpret due to the edge routing in PM being calculated off incorrect input data that was taking into account shapes that were not represented on the screen. To fix this, the system now ensures the edges are routed without taking into account any shapes not represented on the canvas.
SR-A1705 · Issue 205449
Fixed scrumboard intermittent failure
Resolved in Pega Version 7.1.9
After upgrading, it was seen that the scrumboard would intermittently fail to load, partially displaying and then hanging if the columns did not fit within the window boundaries due to the number of elements. This was traced to an error in the functionality that resizes parts of the scrumboard, and has been fixed.
SR-A4995 · Issue 213355
Fixed flow line distortion in Process Modeler
Resolved in Pega Version 7.1.9
When clicking through to a subprocess from a parent flow (by clicking the + sign in the blue subprocess shape), flow lines in the subprocess were shown in a distorted fashion. When opening the same flow in a separate tab (by right clicking the blue subprocess shape and selecting Open Flow) the flow lines were correctly painted. This was an issue caused by the different renderings of the flow depending on whether there was a click through to it (with the + on the parent flow?s subprocess shape), or the subflow was opened in a separate tab (with open Flow). After the Process Modeler saved and checked-in the flow, the connector lines were re-drawn in ways that were non-intuitive and hard to interpret due to the edge routing in PM being calculated off incorrect input data that was taking into account shapes that were not represented on the screen. To fix this, the system now ensures the edges are routed without taking into account any shapes not represented on the canvas.
INC-141579 · Issue 591852
Enhancement added for node heartbeat recovery process
Resolved in Pega Version 8.3.5
Nodes were not showing up in the admin portal even though they were up and running and could be seen in the pr_sys_statusnodes table. The exception "An exception was encountered while invoking the cluster membership listener callback" was seen. All nodes became visible again after multiple restarts. The root cause was traced back to a temporary database connectivity problem. The database itself was fine according to database monitoring reports, but a network problem, a slow database query, or another issue prevented Pega from establishing a connection for more than a minute. An enhancement has been made to resolve this: if a node becomes unhealthy due to the service registry missing due to a failed heartbeat, the heartbeat will try to recover after 60 seconds and keep trying every 30 seconds until it succeeds.
INC-142674 · Issue 594496
Enhancement added for node heartbeat recovery process
Resolved in Pega Version 8.3.5
Nodes were not showing up in the admin portal even though they were up and running and could be seen in the pr_sys_statusnodes table. The exception "An exception was encountered while invoking the cluster membership listener callback" was seen. All nodes became visible again after multiple restarts. The root cause was traced back to a temporary database connectivity problem. The database itself was fine according to database monitoring reports, but a network problem, a slow database query, or another issue prevented Pega from establishing a connection for more than a minute. An enhancement has been made to resolve this: if a node becomes unhealthy due to the service registry missing due to a failed heartbeat, the heartbeat will try to recover after 60 seconds and keep trying every 30 seconds until it succeeds.
INC-137255 · Issue 584910
Resolved Cassandra query read/write latency
Resolved in Pega Version 8.3.5
Read/write latency was seen when certain Cassandra queries were triggered by the system. This was traced to an unusual case where a flush was not done for an exceptionally long time period, and has been resolved.
INC-174661 · Issue 678823
Handling added for clearing node killed between assignment and processing
Resolved in Pega Version 8.6.3
An Offer flow was not resuming after it expired according to the wait shape. Investigation traced this to partitions which were assigned to a dead node in NEW state where they were not picked up by the dataflow. The problem was only encountered in the unusual situation when a dataflow node was killed in the brief period of time between the assignment and the processing, and has been resolved by adding an update which will clear unknown new assigned partitions for the batch run health task.
INC-179879 · Issue 664804
Localization added to DelegateDescription
Resolved in Pega Version 8.6.3
Localization was not working correctly for the description of a delegated rule due to pyDelegeteDescription being defined with a non-localized Property value. This has been resolved by localizing the property value for pyDelegeteDescription.
INC-183211 · Issue 667011
Compare-To-Empty-String support added to Analyzer
Resolved in Pega Version 8.6.3
An enhancement has been added to support a NotEquals decision function in the Analyzer.