INC-222561 · Issue 721043
Check added for destination type for distribution test reports
Resolved in Pega Version 8.6.5
When there were two output destinations in the system, one of type VBD and another of type Database table and both had the same name, an incorrect class was set for distribution test reports and an error was generated when trying to open the report. Investigation showed the system was only checking for the name of the destination and not its type; this has been resolved by adding a pzSetSimulationOutputClass data transform to check for the destination type in addition to the destination name when setting the class for reports.
INC-224038 · Issue 723258
Performance improvement for serviceregistry table queries
Resolved in Pega Version 8.6.5
The expression filter ($1 - "SSR"."pytimeout") in the queries for service registry table caused full table scans which might result in performance issue and even risk of contention/locking. This has been resolved by replacing the pyTimeout column reference in filters to the default value = 9000ms so that performance for these queries can be improved.