INC-155214 · Issue 617006
GetBinaryFilesRef updated for resolving wildcard
Resolved in Pega Version 8.5.3
After upgrading from 8.2 to 8.4, errors related to "Unable to serve file java.lang.IllegalArgumentException: Illegal characters detected in the path" appeared numerous times during full syncs, either on first time login or after cache clear. This was traced to normalizeRelativePath failing, and was caused by a resource declaration in pzGetBinaryFilesRef that encountered an issue where wilcarded URLs were not automatically resolved while packaging Static resources. This has been resolved.
INC-155752 · Issue 622772
Hidden Question pages and answers will be saved to database
Resolved in Pega Version 8.5.3
After a question page was shown and some values were entered, going back to the question and reverting an option caused the question page to not be visible, but the answer values persisted in the clipboard and were eventually saved into the database. This was a missed use case for Question page smart shapes, and has been resolved by updating the pzSetQuestionPageParams data transform so that whenever a question page is evaluated to either to show/hide, when the question page visibility is set to false and the pyClearAnswerValuesWhenQPHidden 'when' rule is overridden, the corresponding values will be wiped from the clipboard and only the required values will be saved to the database. However, please note this is not supported for branching logic and visibility conditions should be used instead.
INC-156211 · Issue 620193
Verbose comments removed from wrapper
Resolved in Pega Version 8.5.3
Comments with references to external links have been removed from some harness wrappers.
INC-157317 · Issue 620573
Signature Capture supported in RDL
Resolved in Pega Version 8.5.3
An enhancement has been added which supports using Signature Capture on forms in repeating dynamic layouts.
INC-157596 · Issue 624124
Mobile channel upgrade wizard correctly initiated
Resolved in Pega Version 8.5.3
After upgrade, the offline mobile app was not loading the correct portal. This was traced to missing properties needed to launch the upgrade wizard for channels upgrading from a previous release to v8.5, and has been resolved by setting those properties in upgrade activities.
INC-158468 · Issue 626380
RecordFieldValuesList page cleared
Resolved in Pega Version 8.5.3
Investigation o0f web node crashes traced the issue to a condition where the RecordFieldValuesList page was not cleared. This has been resolved.
SR-D28060 · Issue 498749
Cross-site scripting filtering added to App Studio
Resolved in Pega Version 8.3.1
The pzDisplaySpaceFeedTitle control which is used to display the audit feed in Pega App Studio has been updated with cross-site scripting filtering.
SR-D28293 · Issue 498233
Pega Survey answer values support special characters
Resolved in Pega Version 8.3.1
When using a Complex radio control (RadioButtonComplexQuestionSurvey), a selected option that used answer values containing special characters was cleared on refresh. This was traced to a mismatch between strAnswer and strValue in the control logic, and has been corrected.
SR-D30428 · Issue 503424
Added handling for deprecated UI Kit in Pulse OpenURLInWindow
Resolved in Pega Version 8.3.1
After upgrade, clicking on a link in a Pulse comment opened a new window with an error message indicating no content was returned. Investigation showed that if an older deprecated version of the UI kit was used, 'Open URL in window' was configured as Run Script function. The more recent versions use an OpenURLInWindow action. To resolve this, the script has been updated to use an action and pass the correct parameters.
SR-D33052 · Issue 502061
Blank space removed in email reply
Resolved in Pega Version 8.3.1
An issue with blank space being added between the CSR icon and the email content for the first customer mail has been resolved by setting the window width to 100%.