SR-D37757 · Issue 507967
Pulse delete icon repaired
Resolved in Pega Version 8.2.4
After upgrade, it was no longer possible to delete one's own comment in Pulse. This was traced to the section pzDeleteMessage having two dynamic layouts with icon as image configured. During runtime, this section was present in the DOM yet the icons were not visible when the conditions configured were returned as true. This was caused by an error in the generated java for the layout, and has been corrected.
SR-D18853 · Issue 503275
Visibility on client check removed to enable Pulse on click
Resolved in Pega Version 8.2.4
When Pulse was configured on click of a icon, the comment section was not visible. Investigation showed that at the time of DOM load, pyMessage property was not available in the DOM because 'Run visibility condition on client' was checked by default. Visibility on client checks have been removed to resolve this issue.
SR-D33491 · Issue 511727
Code fragment removed to resolve CookieDisabledException
Resolved in Pega Version 8.2.4
After upgrade, a CookieDisabledException occurred after a post activity was invoked in the single sign-on (SSO) authentication service. This was traced to the site using the deprecated flag "redirectguests" as part of SSO-based login for mashup usecases. This flag was used to check if a cookiedisabled exception was thrown or not, and if there was no cookie, if a requestor was authenticated in first request. However, the flag has been removed as part of work done to omit the Cookie support check on Mobile App UAs. Code that supported the use of this flag remained after that work and led to the exception being generated, but has now been removed as well.
SR-D43811 · Issue 511921
Code fragment removed to resolve CookieDisabledException
Resolved in Pega Version 8.2.4
After upgrade, a CookieDisabledException occurred after a post activity was invoked in the single sign-on (SSO) authentication service. This was traced to the site using the deprecated flag "redirectguests" as part of SSO-based login for mashup usecases. This flag was used to check if a cookiedisabled exception was thrown or not, and if there was no cookie, if a requestor was authenticated in first request. However, the flag has been removed as part of work done to omit the Cookie support check on Mobile App UAs. Code that supported the use of this flag remained after that work and led to the exception being generated, but has now been removed as well.
INC-182423 · Issue 691800
Pull to refresh disabled during case submission
Resolved in Pega Version 8.6.3
Triggering a refresh (swipe down) on mobile while the spinning loading indicator was shown resulted in the error 'This action is not allowed' instead of being able to view the case. This has been resolved by disabling pull to refresh when there is any background network activity in progress.
INC-183485 · Issue 692519
ClientCache performance optimization
Resolved in Pega Version 8.6.3
In order to improve performance for the mobile app, updates have been made to optimize the ClientCache list interations.
INC-185434 · Issue 674054
Page group property passed correctly for complex questions
Resolved in Pega Version 8.6.3
When the Pega Survey Smart shape was used to configure a list of complex set of questions using Question rules and invoked using the Survey shape, the reload system was not passing the subscript value for the Page group property pyQuestionnaire. This caused an Invalid Reference exception and displayed an error pop up for the end user. Investigation traced this to a call to RefreshList to load a section holding pyQuestionnaire(Subscript) page content which was in place as part of a legacy fix but which has since been made unnecessary due to infrastructure changes in the DOM utilities. To resolve this, the ComplexQuestionCheckboxTemplate and pzComplexQuestionCheckBoxTemplateRowDetails section rules have been updated to remove the RefreshList action on checkbox.
INC-187230 · Issue 672473
Resolved exception during LDP processing
Resolved in Pega Version 8.6.3
A ConcurrentModificationException was appearing during the processing of Large Data Pages. This has been resolved with the addition of a lock on clear method in ConcurrentReplicatedPage.
INC-189511 · Issue 679185
Column width adjusted for Survey simple question text area
Resolved in Pega Version 8.6.3
When a number of columns were entered in a simple question (Answer tab) for a text area, the width was not reduced or increased for the text area. This has been resolved by setting pySpecifyWidth to custom for textarea.
INC-191970 · Issue 677464
Updates made for reviewing online case in an offline app
Resolved in Pega Version 8.6.3
After developing a Field Service Mobile app on Pega 8.3, updating and assessing the Mobile App on Pega 8.6 resulted in a flicker in the back arrow for returning to the work list. This was traced to WebViewManager not being available for online cases in offline apps, and has been resolved by adding an update that will use attachOnload/detachOnload if WebViewManager is not available. In addition, an issue with creating a space or document on mobile has been corrected by using the onViewRendered method instead of attachOnload for the offline app case.