SR-D37275 · Issue 519027
Enabled PDF attachment for iPad Safari
Resolved in Pega Version 8.1.8
It was not possible to select the PDF option when attempting to attach a file while using iPad Safari. This has been corrected.
SR-D76134 · Issue 542160
"Offline" icon shows when simulating offline mode
Resolved in Pega Version 8.1.8
When simulating offline mode by selecting "Settings->SystemInfo->Simulate Offline checkbox" and moving to MyWork, "Offline" did not appear in the header. This has been corrected.
SR-D37757 · Issue 507967
Pulse delete icon repaired
Resolved in Pega Version 8.2.4
After upgrade, it was no longer possible to delete one's own comment in Pulse. This was traced to the section pzDeleteMessage having two dynamic layouts with icon as image configured. During runtime, this section was present in the DOM yet the icons were not visible when the conditions configured were returned as true. This was caused by an error in the generated java for the layout, and has been corrected.
SR-D18853 · Issue 503275
Visibility on client check removed to enable Pulse on click
Resolved in Pega Version 8.2.4
When Pulse was configured on click of a icon, the comment section was not visible. Investigation showed that at the time of DOM load, pyMessage property was not available in the DOM because 'Run visibility condition on client' was checked by default. Visibility on client checks have been removed to resolve this issue.
SR-D33491 · Issue 511727
Code fragment removed to resolve CookieDisabledException
Resolved in Pega Version 8.2.4
After upgrade, a CookieDisabledException occurred after a post activity was invoked in the single sign-on (SSO) authentication service. This was traced to the site using the deprecated flag "redirectguests" as part of SSO-based login for mashup usecases. This flag was used to check if a cookiedisabled exception was thrown or not, and if there was no cookie, if a requestor was authenticated in first request. However, the flag has been removed as part of work done to omit the Cookie support check on Mobile App UAs. Code that supported the use of this flag remained after that work and led to the exception being generated, but has now been removed as well.
SR-D43811 · Issue 511921
Code fragment removed to resolve CookieDisabledException
Resolved in Pega Version 8.2.4
After upgrade, a CookieDisabledException occurred after a post activity was invoked in the single sign-on (SSO) authentication service. This was traced to the site using the deprecated flag "redirectguests" as part of SSO-based login for mashup usecases. This flag was used to check if a cookiedisabled exception was thrown or not, and if there was no cookie, if a requestor was authenticated in first request. However, the flag has been removed as part of work done to omit the Cookie support check on Mobile App UAs. Code that supported the use of this flag remained after that work and led to the exception being generated, but has now been removed as well.
INC-152542 · Issue 610947
Support extended for document tags
Resolved in Pega Version 8.7
An enhancement has been added to extend the support for document tags, including showing tags added to a case in a workpool other than the application workpool; showing tags from other operators such as partner sales rep, sales reps, etc; and displaying tags in the "recently added by me" section.
INC-160485 · Issue 655297
Trailing "/" added to public links for SSO use
Resolved in Pega Version 8.7
Links generated using pyWorkLinkWithLabel were not working with SSO due to not having a trailing "/" on the URL. This has been corrected by adding code to append the "/" if the public link url doesn't end with it.
INC-161214 · Issue 640893
Push notification of shape-created child case opens correct case
Resolved in Pega Version 8.7
In a scenario with two cases, CaseA and its child case, CaseB, when CaseB was created from CaseA with a standard shape and a push notification was sent right after creation, the "Custom message" notification received on a mobile device opened CaseA instead of CaseB. If CaseB was created as a standalone case, the push notification opened it properly. This was traced to an edge case where the Primary.pzInsKey was empty because the child case was not available in database when the push notification payload was created by push shape, leading to the CaseID retrieved by getInstanceHandleFromPage to fetch the parent Case ID instead. This has been resolved by modifying the process to get the pzInsKey from the step page.
INC-161398 · Issue 639855
DataSync SynchronizationResponseStreamer logging enhancements
Resolved in Pega Version 8.7
The PegaRULES log contained "Response page does not match request, will generate failure response" errors even though no functional impact was observed. In order to enhance troubleshooting, additional DEBUG logs have been to DataSyncHandler, SynchronizationResponseStreamer is now logged on INFO level and contains more detail, and the error message has been modified to "Cannot prepare continuation response because offline package was stale. Will generate reset schedule response." to be more informative.