SR-D37757 · Issue 507967
Pulse delete icon repaired
Resolved in Pega Version 8.2.4
After upgrade, it was no longer possible to delete one's own comment in Pulse. This was traced to the section pzDeleteMessage having two dynamic layouts with icon as image configured. During runtime, this section was present in the DOM yet the icons were not visible when the conditions configured were returned as true. This was caused by an error in the generated java for the layout, and has been corrected.
SR-D18853 · Issue 503275
Visibility on client check removed to enable Pulse on click
Resolved in Pega Version 8.2.4
When Pulse was configured on click of a icon, the comment section was not visible. Investigation showed that at the time of DOM load, pyMessage property was not available in the DOM because 'Run visibility condition on client' was checked by default. Visibility on client checks have been removed to resolve this issue.
SR-D33491 · Issue 511727
Code fragment removed to resolve CookieDisabledException
Resolved in Pega Version 8.2.4
After upgrade, a CookieDisabledException occurred after a post activity was invoked in the single sign-on (SSO) authentication service. This was traced to the site using the deprecated flag "redirectguests" as part of SSO-based login for mashup usecases. This flag was used to check if a cookiedisabled exception was thrown or not, and if there was no cookie, if a requestor was authenticated in first request. However, the flag has been removed as part of work done to omit the Cookie support check on Mobile App UAs. Code that supported the use of this flag remained after that work and led to the exception being generated, but has now been removed as well.
SR-D43811 · Issue 511921
Code fragment removed to resolve CookieDisabledException
Resolved in Pega Version 8.2.4
After upgrade, a CookieDisabledException occurred after a post activity was invoked in the single sign-on (SSO) authentication service. This was traced to the site using the deprecated flag "redirectguests" as part of SSO-based login for mashup usecases. This flag was used to check if a cookiedisabled exception was thrown or not, and if there was no cookie, if a requestor was authenticated in first request. However, the flag has been removed as part of work done to omit the Cookie support check on Mobile App UAs. Code that supported the use of this flag remained after that work and led to the exception being generated, but has now been removed as well.
INC-192649 · Issue 706134
Basereference context available for attach content control
Resolved in Pega Version 8.6.4
An "undefined" error occurred when attaching a file using the attach content control in the mobile harness. To resolve this, support has been added to run attachcontent in basereference context. This can be enabled by setting pega.attachToCtxPage to true.
INC-195519 · Issue 698498
Support added for using CFW when Pega server is unavailable
Resolved in Pega Version 8.6.4
Data synchronization changes have been added to allow Client for Windows to work in offline mode without an AppCache manifest.
INC-195601 · Issue 685771
Basereference context available for attach content control
Resolved in Pega Version 8.6.4
An "undefined" error occurred when attaching a file using the attach content control in the mobile harness. To resolve this, support has been added to run attachcontent in basereference context. This can be enabled by setting pega.attachToCtxPage to true.
INC-201633 · Issue 703799
Reload icon disappears when refresh is ready
Resolved in Pega Version 8.6.4
After updating the Field Service Mobile App from Pega 8.3 to Pega 8.6, the wait icon continued to be visible even after the refresh was completed. This has been resolved.
INC-206049 · Issue 703468
Resolved activity registration error for Scan Barcode/QR Code
Resolved in Pega Version 8.6.4
Attempting to add the action 'Scan Barcode/QR Code' to a button generated the warning "Unauthorized request detected : Unregistered request encountered with params pyActivity:pzRunActionWrapper pySubAction:runAct pzActivity:pzScanCode". Investigation showed this was due to the pzScanCode activity referred to in pzpega_control_actions_scanCode.js file not being registered, and has been resolved by adding code to register the necessary events for both button and navigation.
INC-210526 · Issue 705640
Mobile supports icons for file attachment
Resolved in Pega Version 8.6.4
Attaching a file to a case in a mobile browser generated a script error popup. This has been resolved with code to support using icons to attach files on mobile.