INC-157596 · Issue 624791
Mobile channel upgrade wizard correctly initiated
Resolved in Pega Version 8.6
After upgrade, the offline mobile app was not loading the correct portal. This was traced to missing properties needed to launch the upgrade wizard for channels upgrading from a previous release to v8.5, and has been resolved by setting those properties in upgrade activities.
INC-160275 · Issue 628103
Unchecked Include descendant classes in pyFeedUserDetails report definition
Resolved in Pega Version 8.6
After upgrade from Pega 7.4. to Pega 8.4, the use of a custom class 'XX-Data-OperatorLoginDetails' which pattern-inherits from Data-Admin-Operator-ID was causing the error "Union not applied because properties [pyImageFileName, pyEmailAddress, pyUseLocale, pyDefaultTimeZone] are not optimized in Data-OperatorLoginDetails”. This happened when the case manager portal was launched and the report definition pyFeedUserDetails (introduced in newer releases) was running by default, and was due to the presence of a few unoptimized properties when the report definition had "Report on Descendant classes" - include all descendant classes, checked by default. To resolve this, the checkbox to Include descendant classes in pyFeedUserDetails is now set as unchecked by default.
INC-160295 · Issue 635008
Null check added for pzinskey in CSLoadSelectedArticle
Resolved in Pega Version 8.6
In step 5 of CSLoadSelectedArticle, there is a call to pzGetAssociatedTags. Step 1 of pzGetAssociatedTags is an Obj-Browse with MaxRecords set to 100000000, and there is logic to retrieve records where pxLinkedRefFrom = Primary.pzInsKey. If Primary.pzInsKey is null, then the Obj-Browse will fetch all of the records. In order to prevent an unnecessary flood of results, a when condition has been added in the CSLoadSelectedArticle rule to check pzInskey so that when the context is empty the system will not call the pzGetAssociatedTags and return the entire record set.
INC-160851 · Issue 631620
Multiple Pulse attachments deleted correctly from datapage
Resolved in Pega Version 8.6
If a Pulse post had only one attachment, removing the post using the Delete option correctly deleted the attachment from Link-attachment and Data-WorkAttach-File. However, if more than one attachment was present, the attachments were removed from view in the UI but were not deleted as expected from the datapage D_AttachmentList. This caused the pr_data_file table to grow very large. Investigation traced the issue to a 'when' condition in the PegaSocial-Message-ValidateDelete activity that was incorrectly being set to true due to a null value and causing the system to skip the deletefile step. This has been resolved by updating the logic to correctly handle removing multiple attachments on delete of a post.
INC-182423 · Issue 691798
Pull to refresh disabled during case submission
Resolved in Pega Version 8.5.6
Triggering a refresh (swipe down) on mobile while the spinning loading indicator was shown resulted in the error 'This action is not allowed' instead of being able to view the case. This has been resolved by disabling pull to refresh when there is any background network activity in progress.
INC-187230 · Issue 672472
Resolved exception during LDP processing
Resolved in Pega Version 8.5.6
A ConcurrentModificationException was appearing during the processing of Large Data Pages. This has been resolved with the addition of a lock on clear method in ConcurrentReplicatedPage.
INC-194932 · Issue 689290
Handling updated for offlineWorkIDs map
Resolved in Pega Version 8.5.6
Intermittent failures were seen when deleting attachments on Mobile. These were traced to pega.ui.DCUtils being undefined, and has been resolved by populating the offlineWorkIDs map for attachment-related actions.
INC-195519 · Issue 698496
Support added for using CFW when Pega server is unavailable
Resolved in Pega Version 8.5.6
Data synchronization changes have been added to allow Client for Windows to work in offline mode without an AppCache manifest.
INC-195601 · Issue 685769
Basereference context available for attach content control
Resolved in Pega Version 8.5.6
An "undefined" error occurred when attaching a file using the attach content control in the mobile harness. To resolve this, support has been added to run attachcontent in basereference context. This can be enabled by setting pega.attachToCtxPage to true.
INC-206049 · Issue 703470
Resolved activity registration error for Scan Barcode/QR Code
Resolved in Pega Version 8.5.6
Attempting to add the action 'Scan Barcode/QR Code' to a button generated the warning "Unauthorized request detected : Unregistered request encountered with params pyActivity:pzRunActionWrapper pySubAction:runAct pzActivity:pzScanCode". Investigation showed this was due to the pzScanCode activity referred to in pzpega_control_actions_scanCode.js file not being registered, and has been resolved by adding code to register the necessary events for both button and navigation.