SR-D7323 · Issue 493176

Pin Case to Board updated to use unique IDs for different workpools

Resolved in Pega Version 8.3.1

When using the Pin Case to Board functionality, it was only possible to find and pin cases in the default/current work pool of the working access group and not any other cases in any other work pools which allowed access to open/search/process. This was due to pyLabel being used to compare if a value entered was valid, which was not a unique key. To resolve this, the pyValidatePinDetails activity in Pega-Ext-Mentions-Documents, Pega-Ext-Mentions-Cases, and Pega-Ext-Mentions-Groups classes have been updated to compare pzInsKey instead of pyLabel to check for validate pin.

SR-D18853 · Issue 488283

Visibility on client check removed to enable Pulse on click

Resolved in Pega Version 8.3.1

When Pulse was configured on click of a icon, the comment section was not visible. Investigation showed that at the time of DOM load, pyMessage property was not available in the DOM because 'Run visibility condition on client' was checked by default. Visibility on client checks have been removed to resolve this issue.

SR-D37757 · Issue 507966

Pulse delete icon repaired

Resolved in Pega Version 8.3.1

After upgrade, it was no longer possible to delete one's own comment in Pulse. This was traced to the section pzDeleteMessage having two dynamic layouts with icon as image configured. During runtime, this section was present in the DOM yet the icons were not visible when the conditions configured were returned as true. This was caused by an error in the generated java for the layout, and has been corrected.

SR-D44012 · Issue 509880

Added more error handling in pzCreateThumbnail

Resolved in Pega Version 8.3.1

In activity pzCreateThumbnail, a null pointer error was generated at step 2. This was traced to the value of originalImage being null even though there was no error in the image file itself, and has been resolved by adding an error check .

INC-160485 · Issue 655296

Trailing "/" added to public links for SSO use

Resolved in Pega Version 8.5.5

Links generated using pyWorkLinkWithLabel were not working with SSO due to not having a trailing "/" on the URL. This has been corrected by adding code to append the "/" if the public link url doesn't end with it.

INC-167139 · Issue 658620

Functions are packaged with "--" suffix

Resolved in Pega Version 8.5.5

Validation rules were not executed as expected. Investigation showed this was caused by functions referenced in the validate rule through a function alias being packaged without the "--" suffix (for example isNameInvalid--(String) was packaged as isNameInvalid). This has been corrected.

INC-168290 · Issue 663426

Signature Accept callback fires correctly in offline app

Resolved in Pega Version 8.5.5

Clicking on the Accept button in the Pega mobile signature control was not properly calling the necessary pega.ui.signature.acceptSignatureCallback method. This has been resolved by adding code for the Post Success and Failure callback on Signature accept in the offline app.

INC-172124 · Issue 651291

Improved Operator ID selection in Mobile Logs Retrieval section

Resolved in Pega Version 8.5.5

Data-Admin-Operator-ID.pzOperatorsByApplication returns only the first 500 operators, which is insufficient for large-scale use. There was a workaround of turning off paging for this report definition and setting maximum records to a bigger value, but this caused potential performance issues when opening very large users list. To resolve this, an autocomplete control will now be used to select Operator ID in the Retrieve Device Logs section of Mobile Channel. When part of an operator ID is typed into this control, the first 100 best results are shown and may be selected.

INC-172315 · Issue 652602

Resolved intermittent attachment save error

Resolved in Pega Version 8.5.5

A Flow Action error was intermittently being displayed when saving attachments. This was traced to the activity pzUploadAttachmentToDocument-->Step 25 which uses the step page CallExtensionAct which can cause a page null exception if it is not initialized, and has been resolved by adding a Page-New step to initialize the page.

INC-175000 · Issue 657005

Handling added for Address Map control in Microsoft Internet Explorer 11

Resolved in Pega Version 8.5.5

Microsoft Internet Explorer 11 does not support Class, async, await and arrowed functions due to not implementing the necessary EC6 features. This caused Address Map Control to not work in this browser because pypega_map_googlegis js creates a js class. To resolve this issue, alternate methods have been added for use with Microsoft Internet Explorer 11.