SR-D86079 · Issue 548108

Label truncation added for pinned item title

Resolved in Pega Version 8.3.3

While pinning a Space, document, or URL, the length of the item title was causing validation issues if it exceeded 64 characters. This has been resolved by modifying the pzGetPins activity to truncate pyLabel to 64 characters using the truncateLongText function.

SR-D73237 · Issue 539124

Pagination updated to resolve repeating Pulse notes

Resolved in Pega Version 8.3.3

After adding a case and entering 15 Pulse notes, scrolling down resulted in the notes being duplicated. Investigation traced this to entering more than 10 posts in a single interaction on a previously empty case when "Progressive pagination" was enabled for the repeating dynamic layout. On Private Edit, if the pagination was changed to "NONE" then the issue was resolved. Pagination depends on the pzPagingStartDateTime property, which is set on D_pzFeedParams, but since there were no results in this scenario this property was not being set. To resolve this, an update has been made so that pzPagingStartDateTime will be set if it is empty.

SR-D76620 · Issue 544576

Resolved touch events issue with updated Google Chrome

Resolved in Pega Version 8.3.3

After upgrading Google Chrome, touch events on a flow action under the Action Button in a case or on the application under "Launch web interface" were not reacting and the flow actions were not accessed. Investigation showed that Google Chrome's latest upgrade (79.0.3945.130) removed the ontouchstart property in the window, causing the isTouchable capability identification method to fail. This has been resolved by adding a check for navigator.maxTouchPoints to identify for Google Chrome whether the device involved has a touchscreen.

SR-D85551 · Issue 548075

Resolved touch events issue with updated Google Chrome

Resolved in Pega Version 8.3.3

After upgrading Google Chrome, touch events on a flow action under the Action Button in a case or on the application under "Launch web interface" were not reacting and the flow actions were not accessed. Investigation showed that Google Chrome's latest upgrade (79.0.3945.130) removed the ontouchstart property in the window, causing the isTouchable capability identification method to fail. This has been resolved by adding a check for navigator.maxTouchPoints to identify for Google Chrome whether the device involved has a touchscreen.

SR-D82882 · Issue 544165

Special characters excluded in the create tag activity

Resolved in Pega Version 8.3.3

The system was allowing the creation of a tag with special characters at the case level from the Actions tab. This was traced to the pxCreateTag activity 3rd step, which passed the current page parameter without invoking the pyValidateTagName activity. This has been corrected by updating the logic.

INC-152542 · Issue 610947

Support extended for document tags

Resolved in Pega Version 8.7

An enhancement has been added to extend the support for document tags, including showing tags added to a case in a workpool other than the application workpool; showing tags from other operators such as partner sales rep, sales reps, etc; and displaying tags in the "recently added by me" section.

INC-160485 · Issue 655297

Trailing "/" added to public links for SSO use

Resolved in Pega Version 8.7

Links generated using pyWorkLinkWithLabel were not working with SSO due to not having a trailing "/" on the URL. This has been corrected by adding code to append the "/" if the public link url doesn't end with it.

INC-161214 · Issue 640893

Push notification of shape-created child case opens correct case

Resolved in Pega Version 8.7

In a scenario with two cases, CaseA and its child case, CaseB, when CaseB was created from CaseA with a standard shape and a push notification was sent right after creation, the "Custom message" notification received on a mobile device opened CaseA instead of CaseB. If CaseB was created as a standalone case, the push notification opened it properly. This was traced to an edge case where the Primary.pzInsKey was empty because the child case was not available in database when the push notification payload was created by push shape, leading to the CaseID retrieved by getInstanceHandleFromPage to fetch the parent Case ID instead. This has been resolved by modifying the process to get the pzInsKey from the step page.

INC-161398 · Issue 639855

DataSync SynchronizationResponseStreamer logging enhancements

Resolved in Pega Version 8.7

The PegaRULES log contained "Response page does not match request, will generate failure response" errors even though no functional impact was observed. In order to enhance troubleshooting, additional DEBUG logs have been to DataSyncHandler, SynchronizationResponseStreamer is now logged on INFO level and contains more detail, and the error message has been modified to "Cannot prepare continuation response because offline package was stale. Will generate reset schedule response." to be more informative.

INC-164429 · Issue 633222

Map address control works in read only view

Resolved in Pega Version 8.7

The pyTrackingMap control was not showing position when used in read-only mode. This was traced to a missed use case, and was caused by the property handle being considered in order to get the value of the current address, but in the case of read-only the property handle was empty and the address field was considered. To resolve this, in case of a read-only track map, the addressproperty value will be considered instead of the property handle.