INC-202480 · Issue 711699
Resolved report filter section freeze
Resolved in Pega Version 8.7.2
When opening a report with a count column, changing the order of one of the report columns resulted in the report freezing and requiring the report to be closed and re-run. This was traced to a double filter popup appearing that did not close after the column sorting, which happened if the report definition was configured as a summary with an aggregated column such as "Count” combined with a "Do not display group headings" setting on the Report Viewer tab. To resolve this, a new step has been added in the Activity pzPopulateSortOrder to call the pzCancelFilterLogicChanges activity.
SR-C41540 · Issue 378722
Filter indicator color repaired for frozen grid headers
Resolved in Pega Version 8.1
The filter indicator color was not changing for columns when the header of grid was frozen. This has been corrected by updating GenerateGridHTML to generate the correct RDColumnName for freeze header grid columns.
INC-208199 · Issue 706446
Added input null check to resolve loading error
Resolved in Pega Version 8.7.2