INC-187057 · Issue 661617

Pega reference tags persist

Resolved in Pega Version 8.5.5

Cross-site scripting protections have been updated to allow Pega reference tags.

INC-167606 · Issue 657153

Optimization prconfig check added for TableInformationMap

Resolved in Pega Version 8.5.5

A prconfig setting check has been added to the TableInformationMap use of OPTIMIZE_SMA_QUERY during its foreign key lookup.

INC-168368 · Issue 657028

DateTime validation works correctly after importing invalid data

Resolved in Pega Version 8.5.5

After creating DecisionData (Dev studio) and adding a DateTime property to the form, importing records with invalid DateTime values failed with a validation error on the screen and the message "Error while converting format for data type DateTime property name Test_date_format with value scvf" was logged. Attempting to proceed by correcting the DateTime property and uploading worked, but any subsequent imports in the same session silently allowed invalid inputs to be passed without any validation errors and then showed blank date fields. This has been corrected.

INC-169636 · Issue 659533

Navigation icons added for use in offline mobile

Resolved in Pega Version 8.5.5

When using an offline mobile app, clicking on an image / link on the home page for navigation resulted in the error “Resource missing. See client logs.” This was traced to a missed use case that resulted in some icons not being available in the package, and has been corrected by including the following:webwb/py-menu-toggle.png webwb/pzgrid_downarrow.png webwb/pymenuleftarrow.png webwb/pymenurightarrow.png webwb/pymodal_mask_img.png webwb/py-grid-sort-down.svg

INC-170514 · Issue 651709

Filtering updated for UI markup

Resolved in Pega Version 8.5.5

Filtering has been added to the UI code to preserve the browser display appearance but remove inappropriate or potentially insecure markup.

SR-C60247 · Issue 413680

pzRuleFormToolbarPopulateActions works when @ is present in the operator ID

Resolved in Pega Version 8.1.3

Using pzRuleFormToolbarPopulateActions to get all the versions of the rule was not working as expected if the '@' symbol was present in the user ID. This was caused by the Rule-.pzRuleFormToolbarPopulateActions activity not forming the private rules correctly in this use case, and has been fixed.

SR-C65381 · Issue 415189

Added check for pyType when refreshing the Declare_pyDisplay Page

Resolved in Pega Version 8.1.3

The standard behavior of clicking a link in the left navigation of the Pega Diagnostic Cloud manager portal is to open a new thread which automatically adds/updates the Declare_pyDisplay Page. However, in some circumstances opening the work items and clicking the navigation link followed by a refresh/F5 from the Google Chrome browser caused the Declare_pyDisplayDatapage to become corrupted and either froze the screen or caused a new popup window to open. This was traced to a situation where the parameter "pyType" was not present in one of the cases, causing the system to rely on "harnessName" instead. To resolve this, a check has been added that will retrieve pyType from the docObj parameter page of the pzpega_ui_dynamiccontainer.js file if needed.

SR-C67397 · Issue 416252

Added check for missing rule data when using abstract class in CSS

Resolved in Pega Version 8.1.3

Including CSS optimization with abstract class in the Advanced tab of the 'Add Optimization' Screen resulted in a Null pointer exception error. This has been resolved by adding a check for missing data from a rule to make the system more resilient in its handling of a corrupt flow-action clipboard page.

SR-C68069 · Issue 416698

Page group use added to referenced properties context for RDL

Resolved in Pega Version 8.1.3

After upgrade, a stack mismatch error was generated by a previously-working configuration that used a nested RDL with a section under Work- class that itself contained an RDL with Data- property that then included a section from Data -- class which contained another RDL that referred to the Work- Page Group. This error was caused by the use case of page group being missed during implementation of referenced properties in ContextProcessor processListNode, which has now been resolved.

SR-C68993 · Issue 416163

Expression exngine correctly evaluates boolean type property with expression

Resolved in Pega Version 8.1.3

When using a dynamic layout with a visibility condition expression and 'Run Visibility Condition on client' checked, a condition such as .VehicleDetails != '' && .VehicleDetails = true was not being evaluated as expected after upgrade. This issue was related to changes made to the expression engine to get the initial evaluation result at the server side, and was caused by a missed use case for a boolean type property with expression. This has been corrected.