Skip to main content

Resolved Issues

View the resolved issues for a specific Platform release.

Go to download resolved issues by patch release.

Browse release notes for a selected Pega Version.

NOTE: Enter just the Case ID number (SR or INC) in order to find the associated Support Request.

Please note: beginning with the Pega Platform 8.7.4 Patch, the Resolved Issues have moved to the Support Center.

INC-170258 · Issue 645042

Removed unneeded query parameter in UI

Resolved in Pega Version 8.5.4

When using an Ajax container without a dynamic container, a refresh harness / section event call related to pyBlockUnregisteredRequests was not being properly registered, resulting in a 403 error and the message "Unregistered request encountered ..". This was traced to a "pyDataTransform=" query parameter that was present in the PZPEGA_UI_MICRODC file, and the parameter has been removed to resolve this issue.

INC-170304 · Issue 645810

PDF generation corrected

Resolved in Pega Version 8.5.4

Issues with PDF generation have been resolved by upgrading the PD4ML libraries to version 4.0.9fx5.

INC-171121 · Issue 648131

Filter popup persists correctly

Resolved in Pega Version 8.5.4

When the Apply filter option was selected for a table configured with page list property as source, the filter popup appeared on the screen but disappeared after 3 to 4 seconds. This has been resolved by enabling the stretch for tabs option in the layout group.

INC-172521 · Issue 651551

Email template content visible in user application

Resolved in Pega Version 8.5.4

An issue was seen with email templates functionality where the body content given during the email template creation was not visible when the template was used in the application by an end user. This was a missed use case for recent security updates, and has been resolved.

INC-174699 · Issue 652070

Work objects can open in multiple tabs with Layout group

Resolved in Pega Version 8.5.4

After implementing the Worker portal with Layout Group(Tab) to open work objects and other options (Pulse, Spaces, My Cases etc.) in multiple tabs, the tabs opened as expected the first time but after all of the tabs were closed any newly opened cases appeared in popup windows instead of tabs. Investigation showed that when the last tab was closed, the display was set to the main div container of the ajaxcontainer so opening the work object again used a new window. Tab Group has been deprecated in the current Pega version, but the site has a requirement to open the cases in same way as they appeared with Tab Group; to resolve this, support has been added by making the width 0 for the active header highlighter instead of using display none for the main container for this configuration.

INC-174921 · Issue 652320

Client Side required validation applied to dropdown Date field

Resolved in Pega Version 8.5.4

The mandatory validation on submit of the screenflow screen was not being triggered even though 'Required' was configured on the Date field.This was traced to the validation being applied to a hidden field when the date time control is configured in dropdown mode, and has been resolved by adding a condition for validating this configuration.

INC-155878 · Issue 645364

Class list updated when using ActivateDocument in portal navigation

Resolved in Pega Version 8.5.4

Global search worked the first time it was used, but failed after another case was opened from the dashboard or there was a click on any landing page home, dashboard, or space. Investigation showed this was caused by the pySearchText being blank in the clipboard, which was traced to a harness context issue related to pega.desktop.activateDocument being used in pzPortalNavigation on DynamicLayout with Application Logo and Application label. To resolve this, an update has been made that will update the class list with the proper one when the data-harness-id is set.

INC-166995 · Issue 642440

DeleteDocumentPg added to allow list

Resolved in Pega Version 8.7

During performance testing with CSRF settings enabled, a '403 Forbidden' error was seen in the network trace when FinishAssignment called pyActivity=pyDeleteDocument on close action. This has been resolved by adding pyDeleteDocumentPg to the list of allowed activities.

SR-D79178 · Issue 543310

SameSite cookie setting added for Mashup support in Google Chrome v80+

Resolved in Pega Version 8.3.3

The Google Chrome browser version 80 and above now treats SameSite with a blank value as "Lax" by default, causing mashup scenarios to break. In order to compensate for this change, support has been added for setting SameSite=None in Cookie Settings; this value automatically includes the “secure” cookie flag, which enforces HTTPS for the Pega server and mashup. For mashups to work, SameSite should be set as None. Create a Dynamic system setting in the Pega-Engine RuleSet with the name “security/csrf/samesitecookieattributevalue” and the value "None" and restart the server. (The SameSite value "None" works only in secure HTTPS connections.)Note: The SameSite cookie may be set to None/Lax/Strict, based on the requirement. For cookie requirements other than mashup, it should be set as either Strict or Lax, depending upon your application.

SR-D92352 · Issue 553615

Completed onChange will reset FileInput value to null

Resolved in Pega Version 8.3.3

When attaching a file using the "Select File" button, it was not possible to attach the same file after deleting it. Re-attaching the file worked as expected when using Drag and Drop. Investigation showed that the onchange event occurred only when the value of an element was changed, so in this case trying to attach the same file did not change the value of the element and did not fire the onchange. To resolve this, the value of FileInput in pzMultiFilePath Control will be set to null at the end of the onChange event so that an onChange event will be triggered next time even if the same file is added.