INC-154680 · Issue 619027
Moment timezone library update
Resolved in Pega Version 8.4.4
In order to reflect updates such as Brazil discontinuing DST time, the moment timezone libraries have been updated to the latest available version.
INC-154855 · Issue 616002
Updated expression handling when not using client side validation
Resolved in Pega Version 8.4.4
After upgrade, a declare expression used to calculate the end date when creating a schedule case was not populating the result. This was traced to a missed use case for evaluating expressions when 'Enable client side validation' is unchecked, and has been resolved.
INC-156992 · Issue 619707
Show-stream/html repaired for custom portals
Resolved in Pega Version 8.4.4
After upgrade, show-stream/html in activity was not getting executed properly on custom portals. ShowDesktop was modified in 8.1 for AssociateRequestor implementation. As part of that, the custom portal step was moved to the new activity pzPopulateRequestor which is invoked from ShowDesktop. The JUMP condition in step is exiting the pzPopulateRequestor activity, but not ShowDesktop as was the case in the previous versions. To resolve this, the JUMP condition (.pyDesktopType=="Custom") has been added in ShowDesktop at the pzPopulateRequestor call step.
SR-C39293 · Issue 384291
Optimization added for Oracle queries
Resolved in Pega Version 8.3
Certain versions of Oracle may suffer from sporadic poor performance with all_constraints queries. To alleviate this, Pega has been updated to provide some processing optimization where possible in the TableInformationMapImpl function. Additional timing alert and debugging logic has also been added in this class for all platforms, especially for lookupForeignKey.
SR-C59769 · Issue 399683
Chart fixes for localization and filtering
Resolved in Pega Version 8.3
A problem was seen with a chart where the column was a date and its labels were not localized even though the values were displayed in the data grid correctly. This was resolved by updating the pzMultiSeriesData XML Stream to generate the series name attribute with the localized value. An issue with a drill down report pulling the data for entire criteria on click of specific set even though the summary view or clicking on the report data worked correctly has been fixed by adding an enhancement for using the aggregate column as a filter on drilldown with "Is not null". Additional work was also done to resolve an issue of a broken case causing the chart not to render when the aggregates were in an unexpected order.
SR-C72337 · Issue 414084
Atmosphere cross-site scripting Vulnerability fixed
Resolved in Pega Version 8.3
Atmosphere has been updated to close a potential cross-site scripting vunerability.
SR-C88178 · Issue 414108
docx4j jar updated for compatibility with Office365
Resolved in Pega Version 8.3
After generating a docx file with Office365, an error appeared indicating the document had invalid XML data and couldn't be opened. Once the error message was dismissed, the file could be opened normally. This was caused by an incompatibility between Office365 and the Plutext docx4j jar, and the Plutext jar has now been updated to version 6.1.1 to resolve this issue.
SR-C65381 · Issue 415187
Added check for pyType when refreshing the Declare_pyDisplay Page
Resolved in Pega Version 8.3
The standard behavior of clicking a link in the left navigation of the Pega Diagnostic Cloud manager portal is to open a new thread which automatically adds/updates the Declare_pyDisplay Page. However, in some circumstances opening the work items and clicking the navigation link followed by a refresh/F5 from the Google Chrome browser caused the Declare_pyDisplayDatapage to become corrupted and either froze the screen or caused a new popup window to open. This was traced to a situation where the parameter "pyType" was not present in one of the cases, causing the system to rely on "harnessName" instead. To resolve this, a check has been added that will retrieve pyType from the docObj parameter page of the pzpega_ui_dynamiccontainer.js file if needed.
SR-C71520 · Issue 415398
Robot Manager portal re-launch correctly renders the last active screen
Resolved in Pega Version 8.3
Two problems were seen with Robot Manager:1) Opening Robot Manager and then navigating to Workgroup drill-in screen worked as expected, but when the portal was closed and re-launched from Designer Studio, the last active screen (workgroup drill-in) was rendered but with no valid data in it. 2) Opening Robot Manager from email notification worked the first time, but when the same button from the same mail was clicked, the last active screen was rendered with blank or no valid data. This was caused by preActivity and preActivityParams not being sent in the doUIAction call during re-launch of the portal, and has been fixed.
SR-C64192 · Issue 415846
Activity Run allows autocomplete control for data transform
Resolved in Pega Version 8.3