SR-D60375 · Issue 527755

Resolved upgrade SqlSyntaxErrorException

Resolved in Pega Version 8.1.8

When trying to perform an in-place update, the error "SqlSyntaxErrorException" appeared. Investigation showed that DDL statements for Adding 'pzInsKey' as PrimaryKey for Tables pc_work and pr_sys_locks were generated during the upgrade while pzInsKey was already the PrimaryKey in corresponding tables. This has been corrected.

SR-D65112 · Issue 541147

Added support for imported rules to populate bixreportpage

Resolved in Pega Version 8.1.8

Extract rules were not holding the filter criteria after upgrade while performing save-as (for the first time) of the imported rules from the previous version. Criteria were held when the filters were created in the new version. This was caused by BIX extracts created in earlier releases (7.x) not having bixreportpage included. When an environment was upgraded to 8.x versions, opening an extract required the bixreportpage to be populated with Report Definition metadata including the filters defined in the actual extract. Although the filters from the original extract were converted to filters that are acceptable by ReportDefinition, they were not being added to bixreportpage on opening the extract. To resolve this, the system has been updated to copy the filters back to bixreportpage on opening the extract in the upgraded environment.

SR-D66986 · Issue 539412

BIX command line support improved

Resolved in Pega Version 8.1.8

Post-upgrade, it was seen that changes to the engine which validate that Data-Admin-DB-Name is not defined multiple times caused the BIX command line extracts to no longer work the same way. In order to improve backwards compatibility, updates have been made to loosen the validation in JdbcConfigurationFactory to always prefer prconfig settings if there are multiple definitions.

SR-D71977 · Issue 535600

Obj-Browse will retrieve more than 50 records

Resolved in Pega Version 8.1.8

After performing multiple skims, a newly added property was not retrieved when an Obj-Browse was performed. In Obj-Browse action, when a class is mapped to an external table and does not contain BLOB column pzpvstream, in a specific case where pxObjClass value is a reference to a parameter, a list of properties mapped to the class explicitly by querying pr4_rule_property table using NativeSQL is fetched. This call by default returns only 50 records: in cases where there are more than 50 properties for an external class, some of the properties from the obj-browse response mapping are therefore missed. To resolve this, the limit of 50 records has been removed from this NativeSQL call.

SR-D79565 · Issue 541532

BIX extracts traverse up from embedded pages to find target tables

Resolved in Pega Version 8.1.8

For BIX Extracts with Output Format : Database Schema, the target table name was not being generated if the properties were buried under two levels of Embedded Pages. Instead, in case of multiple nested levels of PAGE property types, the system ended up referring the immediate Parent page or its parent PAGE for pySourceName. Since this is of type PAGE, an empty value was returned for the target table name and the extract would fail. To resolve this, the system has been updated to traverse up the node parents until the correct target table name is found.

SR-D38318 · Issue 519715

Data pages explicitly cleared after QP use

Resolved in Pega Version 8.1.8

The Util Node was showing as Offline in the Search Landing Page, and when Jobs were submitted for execution from other Nodes the message "Detected active run with unreachable nodes" was logged. The util node, configured as a backgroundprocessing node, was running QPs; the queue size for custom QPs is 500 messages /queue items per minute, but investigation showed the requestor level and thread level data pages corresponding to the QP activities were not being cleared after use. This led to high heap memory issues that made the node unreachable, and has been resolved by adding code to explicitly remove the data pages when processing has finished.

SR-D60830 · Issue 533028

Logic update for classloading synchronization

Resolved in Pega Version 8.1.8

The synchronization logic for classloading has been updated to resolve intermittent deadlocking seen when two DataFlow threads are executing a distribution test.

SR-D61253 · Issue 527654

Exception stack trace will be included as comments in generated assembly code

Resolved in Pega Version 8.1.8

When there is an exception during assembly time, that original exception message is assembled in the generated code. To improve the process of finding the the root cause by examining the original exception stack, the system has been updated to insert the original exception stack trace into the generated code as comments.

SR-D75649 · Issue 547565

OrgChartWorkGroup update issue resolved

Resolved in Pega Version 8.1.8

The instances of Index-PegaFS-Data-OrgChartWorkGroup table were corrupted after adding a new department via the landing page. This was traced to the missed scenario of a Page-Copy with declare index present in it, and has been resolved.

SR-D84880 · Issue 546890

Null check added to resolve addmapcasetomap error

Resolved in Pega Version 8.1.8

Using a createcase flow shape to create child cases by looping on a page list on the parent case resulted in pzaddmapcasetomap throwing an exception related to the activity pzLoadCaseHierarchyWrapper in step 5. This was traced to a page being removed after the list of pages was received in findPageByHandle, and has been resolved by adding a null check.