INC-163292 · Issue 635837
Portlet service deprecated
Resolved in Pega Version 8.4.6
Portlet authentication services have been removed from the standard installation package.
SR-C81829 · Issue 419227
pxCoveredCountOpen value decrease corrected
Resolved in Pega Version 8.2.1
When a flow reached the resolved stage (Resolved-Withdrawn), pxCoveredCountOpen was reducing the count by 2 instead of 1, eventually causing the value to go negative and prevent any further work objects from being marked as Withdrawn. Investigation showed the "Update status" activity was being called twice due to the Temporary WorkPage used to delete assignments persisting and appearing as a duplicate pyWorkPage. This caused an issue when using findPage by pzInsKey. To correct this, the "pxDeleteAssignmentsForWork" activity for Step-15 has been modified to explicitly remove the temporary WorkPage after the assignment is deleted.
SR-C85035 · Issue 421947
Added getIfPresent check for Field Value parameters with pzAPICreateJsonForView
Resolved in Pega Version 8.2.1
Calling pzAPICreateJsonForView was altering case values if localized field value parameters were added. This has been corrected by performing a getIfPresent and getIfString on the property pyFieldValueParams so field value parameters will not be added to the main page if they're not present.
SR-C82244 · Issue 421173
Enhancement made to allow passing of URL in actionset via the DX API
Resolved in Pega Version 8.2.1
When using the action "Open URL in Window" and the option "Use Alternate Domain" to pass a URL that is in saved in a property, the name of the property was passed when using the DX API instead of the URL. To allow this use, an enhancement has been added to support storing a last submitted value and a reference so that an action set with a property reference can return a reference object with lastSavedValue and the reference name attached.
SR-C83915 · Issue 421168
Enhancement added to support property reference name for section include
Resolved in Pega Version 8.2.1
When requesting the view of a section from a repeating dynamic layout where the name of the section is taken from a property, the DX API returned an error on the tracer indicating "Invalid value for aReference passed to com.pega.pegarules.data.internal.clipboard.ClipboardPageImpl.getString(String)". This has been resolved by adding an enhancement to support using a property reference for section include.
SR-C75566 · Issue 420773
Added null check to avoid DisplayCardAccountHeader rendering issue
Resolved in Pega Version 8.2.1
When the out of the box section DisplayCardAccountHeader was created by View editor and then converted to full section editor, the embedded sections were empty or not seen. This was traced to the design view javascript hitting an error which caused the design view rendering to fail. To correct this, pzpega_ud_gridlayout_model has been updated to wrap the line in question with a null check and set the value to empty string if it doesn't already exist in the model.
SR-C83808 · Issue 421298
FIRST aggregate in bucketed window fixed
Resolved in Pega Version 8.2.1
FIRST aggregates were not giving the correct results if used in a Sliding Time window together with an average aggregate.This was traced to an incorrect implementation of FirstAggregatorHolder.substractAggregate which used propertyIndex to get aggregate value (which was not correct in this context), and has been fixed by using the correct index in FirstAggregatorHolder class.
SR-C80215 · Issue 421849
Migrated Data Flows open correctly from the data flow landing page
Resolved in Pega Version 8.2.1
After upgrade, Data Flows made in an earlier version could not be opened from the data flow landing page. Instead, a generic error screen was displayed and an NPE on activity pxMigrate was logged. This was caused by a missing null pointer check, and has been corrected.
SR-C82408 · Issue 422327
Repaired instance insertion for REST connection invoked via Queue
Resolved in Pega Version 8.2.1
After upgrade, the REST connection invoked in an activity which in turn called OOTB ProcessQueue was not getting the response into the SYSTEM-QUEUE-EXECUTIONREQUEST-CONNECT-CREATEBOOKING instance. The right response was observed coming from other source systems in the logs, and the work object status also changing as expected. This has been resolved by exposing a DSS to revert to the old behavior of Response being present in the queueItem when a connector is queued for execution.
SR-C82480 · Issue 421487
Column Headers properly aligned after expand/collapse of Tree Grids
Resolved in Pega Version 8.2.1
When using a hierarchical table - tree grid with a configuration that included Width of content-Pixels(Fit Content), a Fixed (pixel) size grid, and Freeze Header, expanding and collapsing back the contents resulted in a misalignment of the column headers. The fixed header implementation makes use of multiple table layouts which have to kept in sync via javascript; this issue has been resolved by rewriting the fixed header implementation to call setHeadersWidth on expand/collapse of a treegrid row.