INC-160102 · Issue 627687

Updated resource file paths for mobile images

Resolved in Pega Version 8.5.3

After upgrade, a resource missing error was shown on the mobile UI when accessing a section in an offline mobile app. This was traced to the CSS file having an incorrect path to the 'requiredstar' gif file and has been resolved by updating pzbase-form-level-elements to use webwb instead of an images path

INC-160497 · Issue 627715

Able to add missing headers from App Studio

Resolved in Pega Version 8.5.3

A missing header in pyActionArea and pyActionAreaheader could not be added from App Studio. This was due to the sections not being built using design templates, and has been resolved by updating the section to be editable in runtime.

INC-160500 · Issue 627268

Cosmos App Studio icons have helper text

Resolved in Pega Version 8.5.3

Enhancements have been made for accessibility by adding Helper text to icons in the Cosmos theme for App Studio.

INC-161430 · Issue 627721

Accessibility Component/Widget role added to pyCaseErrorSection

Resolved in Pega Version 8.5.3

Page level errors were not accessible due to the error section being wrapped inside a dynamic layout whose contents were not readable. This has been resolved by updating dynamic layouts to use the correct accessibility roles.

INC-162692 · Issue 629637

Added primary portal navigation role

Resolved in Pega Version 8.5.3

While in the User portal, Accessibility inspector displayed the warning "Primary Portal navigation may be missing a navigation role." This role has now been added to pzPortalNavigation.

SR-D82148 · Issue 547576

Localization improved for ToolTips

Resolved in Pega Version 8.5.3

Attempting to use the Field value to localize the tooltip for Hour and Minute resulted in the time being displayed as "tooltip: Hour". Support has been added for localizing these fields using pyTooltip. In addition, an issue with the tooltip still being displayed after switching helper text to None and saving (without manually clearing the existing text) has been resolved with an update that will clear the tooltip value when helper text is selected as 'None'.

SR-C86126 · Issue 423259

CSV import for delete date values will be formatted before row processing

Resolved in Pega Version 8.1.4

In order to support using CSV import for delete purposes, date/time class keys will be formatted before processing the row.

SR-C80129 · Issue 425385

Enhancement added to hide class join warning from end user

Resolved in Pega Version 8.1.4

An enhancement has been added to hide the joined class warning message at the end user portal if the section pzManageRecords is delegated to the user. This is done by by checking pxLimitedAccess on the pxThread clipboard page.

INC-161463 · Issue 638000

Case Dependency corrected for different access groups

Resolved in Pega Version 8.3.6

Creating a queue item as part of the case dependency was not working as expected when the access groups of the dependent cases were different. Investigation showed that in this scenario, the logic was looping differently and the DependencyList page in pxCheckFlowDependencies was getting removed. To resolve this, the DependencyList page has been moved so it is processed inside the DependencyList.pxResults loop.

INC-163154 · Issue 638097

Code updated for bulk actions buttons

Resolved in Pega Version 8.3.6

After upgrade, hovering over the "Filter case" button in pzBullkUpdate and the "Create" and "Clear" buttons in pzBulkAddActions caused them to disappear. The warning "This button generates markup that was used to support the older browsers. It is recommended that you update it to the newer markup" was shown, and an update code button appeared. Some custom rules exhibited the same behavior initially, but worked as expected after updating the code and saving them. This has been resolved by updating the buttons in pzBulkUpdate and pzAddBulkActions with the latest UI technologies used for button control codes.