Skip to main content

Resolved Issues

View the resolved issues for a specific Platform release.

Go to download resolved issues by patch release.

Browse release notes for a selected Pega Version.

NOTE: Enter just the Case ID number (SR or INC) in order to find the associated Support Request.

Please note: beginning with the Pega Platform 8.7.4 Patch, the Resolved Issues have moved to the Support Center.

INC-142589 · Issue 595489

Corrected tooltip evaluation for multiselect

Resolved in Pega Version 8.4.3

After adding help text for a multiselect help icon with overlay on hover field, the value was not being sourced. Changing to a different type of help text or control type worked as expected. This was due to an error in case sensitivity, using pyToolTip when it should have been pyTooltip, and has been corrected.

INC-142714 · Issue 596554

Recent Cases from different applications available to open

Resolved in Pega Version 8.4.3

An enhancement has been added which will allow opening other application assignments in the Recent Cases section of the current application when the user has access to multiple applications.

INC-143005 · Issue 596954

Fluid Overlay displays as expected in Firefox

Resolved in Pega Version 8.4.3

After upgrade, using the Overlay format "Fluid" to perform the screening matches task in CLM using Firefox had an overlay that covered the entire screen but was missing the scrollbar to manage the content. This has been resolved by adding changes to support dynamic content (with scrollbar) for center overlay.

SR-D16427 · Issue 497220

Multi-nodes rebuild LibraryMetadata to ensure all Rule-Utility-Functions are present on change

Resolved in Pega Version 8.3.1

When performing a complete Application import into a clean installation, references to certain Rule-Utility-Functions went unresolved during the initial assembly. Investigation showed that after introducing a new Rule-Utility-Library or Rule-Utility-Function on one node in a cluster and then generating that, the other nodes in the cluster did not have the correct LibraryMetaDataCache for that Rule-Utility-Library. Therefore assemblies on those other nodes could be bad and throw a runtime UnresolvedAssemblyError. This has been resolved by modifying the way the Library subsystem processes the node changes events for Library Generation to ensure that each node completely rebuilds the LibraryMetadata for that Rule-Utility-Library so it contains all the Rule-Utility-Functions.

SR-D32441 · Issue 502572

Multi-nodes rebuild LibraryMetadata to ensure all Rule-Utility-Functions are present on change

Resolved in Pega Version 8.3.1

When performing a complete Application import into a clean installation, references to certain Rule-Utility-Functions went unresolved during the initial assembly. Investigation showed that after introducing a new Rule-Utility-Library or Rule-Utility-Function on one node in a cluster and then generating that, the other nodes in the cluster did not have the correct LibraryMetaDataCache for that Rule-Utility-Library. Therefore assemblies on those other nodes could be bad and throw a runtime UnresolvedAssemblyError. This has been resolved by modifying the way the Library subsystem processes the node changes events for Library Generation to ensure that each node completely rebuilds the LibraryMetadata for that Rule-Utility-Library so it contains all the Rule-Utility-Functions.

SR-D22113 · Issue 498312

Multi-nodes rebuild LibraryMetadata to ensure all Rule-Utility-Functions are present on change

Resolved in Pega Version 8.3.1

When performing a complete Application import into a clean installation, references to certain Rule-Utility-Functions went unresolved during the initial assembly. Investigation showed that after introducing a new Rule-Utility-Library or Rule-Utility-Function on one node in a cluster and then generating that, the other nodes in the cluster did not have the correct LibraryMetaDataCache for that Rule-Utility-Library. Therefore assemblies on those other nodes could be bad and throw a runtime UnresolvedAssemblyError. This has been resolved by modifying the way the Library subsystem processes the node changes events for Library Generation to ensure that each node completely rebuilds the LibraryMetadata for that Rule-Utility-Library so it contains all the Rule-Utility-Functions.

SR-C49664 · Issue 435310

Updates made for usage validation utility Run report checkbox and buttons

Resolved in Pega Version 8.1.5

The 'Review mode only' checkbox wasn't working for any browser, and the 'Run Report' button wasn't working in IE. This has been resolved by updating the javascript used to invoke the Run Report button to be better integrated with IE, and by adding additional handling to set the ID for the checkbox.

SR-C74677 · Issue 418339

ADM pulse timing changed to inprove performance on very large clusters

Resolved in Pega Version 8.1.5

ADM uses a pulse that checks if any models need to be updated. This uses a Cassandra query which has no "where" clause, causing poor performance for very large clusters. For immediate relief of this issue, the pulse configuration has been updated to increase the timing from 30 to 300 seconds so it fires less often. Model updates typically happen every x hours and often the pulse will not detect any models that would need to be updated. Further improvements in this process will be available in a future release.

SR-C77730 · Issue 437101

Resolved case lock release improved

Resolved in Pega Version 8.1.5

Cases created through the create work object were unnecessarily holding onto locks for up to two hours. This was traced to a defer-write scenario for mobile devices which did not return the correct status needed for "no further assignments". In order to resolve this issue, a new parameter "returnNextActionInfo" of type boolean has been added to svcPerformFlowAction. This parameter will be always set as false when calling this activity from sync up so all locks will be closed and released.

SR-C80622 · Issue 424876

GenerateContainer updated to prefer icon given in skin over hardcoded icons

Resolved in Pega Version 8.1.5

When trying to change the Expand/Collapse icon for dynamic layout by defining a custom format in the app skin, changes made in the Expand icon image and Collapse icon image were not reflected. This was due to the CSS selector being overriden with a hardcoded arrow icon instead of automatically taking the icon from the skin rule. To resolve this, the selector and conditions used in GenerateContainer.java have been modified such that the icon added in the skin should be picked automatically instead of any hardcoded icon available.

We'd prefer it if you saw us at our best.

Pega.com is not optimized for Internet Explorer. For the optimal experience, please use:

Close Deprecation Notice
Contact us