INC-202480 · Issue 699082
Resolved report filter section freeze
Resolved in Pega Version 8.6.4
When opening a report with a count column, changing the order of one of the report columns resulted in the report freezing and requiring the report to be closed and re-run. This was traced to a double filter popup appearing that did not close after the column sorting, which happened if the report definition was configured as a summary with an aggregated column such as "Count” combined with a "Do not display group headings" setting on the Report Viewer tab. To resolve this, a new step has been added in the Activity pzPopulateSortOrder to call the pzCancelFilterLogicChanges activity.
INC-217655 · Issue 723564
Resolved validation check freeze for Dynamic Layout Group
Resolved in Pega Version 8.6.5
After creating a multi-step form where step 1 had a Dynamic Layout Group(tabbed) that used form fields configured with validations, clicking next with empty/invalid values in the form intermittently caused the screen to freeze and a javascript exception was logged. This was traced to a missed use case related to templates in the childNode, and has been resolved by adding the necessary safe checks in lgtemplate and lgcelltemplate.
INC-208199 · Issue 706447
bbbAdded input null check to resolve loading error
Resolved in Pega Version 8.6.4
The application was freezing while loading if action was taken on the controls while a page level message was visible. This has been resolved by adding an additional null check for input before calling the focus API.
SR-C97873 · Issue 437282
Added check to maintain key value when using collapseAllMenu in child navigation menu
Resolved in Pega Version 8.1.5
After a navigation menu had a child added as reference navigation menu that used the function collapseAllMenus, the screen was freezing if a link was clicked in the added child navigation and a javascript error appeared on the console screen. This was traced to an improper key being set in sessionStorage object in setItem due to the nesting, and has been corrected by adding a check in sessionstorage setitem to maintain the proper key value.
INC-166845 · Issue 640299
Hazelcast remote execution not called from synchronized context
Resolved in Pega Version 8.7
After navigating to the Admin Studio portal to view the nodes, the portal was temporarily freezing. Investigation of the thread dump revealed this was caused by a DDS pulse sending a remote execution call to all nodes to update logger settings even though the site was not using DDS. This has been resolved by updating the system to avoid calling Hazelcast remote execution from a synchronized context.
INC-180233 · Issue 660578
Offline.Rulecache UI module capacity increased
Resolved in Pega Version 8.7
Clicking the save button on a modal window caused the application to freeze and all the buttons were disabled. This was traced to the pega.offline.rulecache UI module having a default hard limit of 500 rules. Once the hard limit was reached, the system intermittently silently refused caching additional rules depending on the amount of rules packaged or the order in which the rules are loaded to the cache. To resolve this, the system has been updated to only log a console warning once the maximum threshold is reached, allowing the application to operate normally and at the time inform about the potential impact of having too many rules in memory.
SR-D52144 · Issue 515672
When no active document is available on login, first document will be marked active
Resolved in Pega Version 8.2.5
After logging into the user portal, attempting to perform operations like (opening a case/work object, opening reports etc.) caused the browser request to spin or freeze. The only way to recover was to close and re-launch the browser window/session and re-login. This issue occurred when there was an active reportdefinition document before the browser/node crash in the tabless dynamic container(DC) portal. After recovery, the dynamic container did not recreate the report definition document but instead tried to activate the first document in the portal, which in this case was the default harness configured in the Dynamic Container. As it was not yet loaded, exceptions were thrown. To resolve this, when no active document is available, the first document will be marked as the active document.