SR-C93292 · Issue 432662

Inline error messages linked to input for accessibility

Resolved in Pega Version 8.2.3

In order to support accessibility for server side inline messages, the controls have been mapped to the error message div and an aria-describedby attribute has been added for the same. This allows JAWS to read the error message specific to the control where the error occurs.

SR-D20763 · Issue 500406

DASS added to allow toggle of indexpurpose filter in declare index join

Resolved in Pega Version 8.2.3

A performance issue was seen when using a declare index join to add a pxIndexPurpose filter to a very large index_workparty table, either taking a long time to process a search request or intermittently timing out. This was traced to recent modifications in the DeclareIndex Join filter conditions to better handle multiple declare index rules pointing to the same index table, As a result, doing a declare index join on one of the declare indexes returned results that included those that corresponded to other declare index rules. To resolve this, a DASS has been provided to toggle the inclusion of the indexpurpose filter in a declare index join to allow for better customization.

INC-166995 · Issue 642440

DeleteDocumentPg added to allow list

Resolved in Pega Version 8.7

During performance testing with CSRF settings enabled, a '403 Forbidden' error was seen in the network trace when FinishAssignment called pyActivity=pyDeleteDocument on close action. This has been resolved by adding pyDeleteDocumentPg to the list of allowed activities.

SR-C84033 · Issue 422745

Added handling for legacy page adaptors to get all messages

Resolved in Pega Version 8.2.2

If a validation message was present on the Clipboard, the front-end screen was turning blue and displaying the error "There has been an issue, please consult with administrator". This happened when getMessagesAll was called for pyWorkPage and an auto-populate property was present in the embedded pages/properties. To resolve this, cast has been removed when getting all messages and a new API has been added for legacy page adapters to get all messages.

SR-D10966 · Issue 475333

IH summary behavior change reverted

Resolved in Pega Version 8.2.2

Changes introduced to Interaction History aggregations in 8.1 intended to better align them with the existing behavior of the Interaction History shape in Strategy produced the unexpected side effect of lots of empty records. Based on feedback, the decision has been made to revert the IH aggregation behavior change.

SR-C96456 · Issue 436307

Autocomplete grid scroll bar fixed for large DataPage results

Resolved in Pega Version 8.2.2

When autocomplete (default setting) was present inside a grid and the result popup had < 20 results, the scrollbar was not coming up in Google Chrome. This has been resolved by modifying the fixGridWidthIfRequired API to set set vertical scroll to auto.

SR-C97399 · Issue 439742

Button type added to allow grid expand in Edge

Resolved in Pega Version 8.2.2

When using an expand pane grid in a modal with the Edge browser, clicking on the expand icon using the enter key was throwing an error in new window. This was traced to an issue with a hidden non-auto-generated button in the pzModalHelp control not having a default type, and has been resolved by adding type="button" in the control so Edge will treat it as a submit button.

SR-D10100 · Issue 463307

Bulk actions filter works properly when additional filters are added

Resolved in Pega Version 8.2.2

The Bulk Actions filter was not working if other filters were used in conjunction with it. Investigation showed that when 'assigned to operator' was given a value, the values were fetched properly. When an additional condition was added, the section 'pyBulkProcessingSearchSection' activity called 'pzDefaultOperators' which then set the 'pyUserIdentifier' value to null, and no results were returned. As the activity already had a step to check if the .pyUsage!="Operator" and only then property-set, pyUserIdentifier = "", the subsequent step to set the pyUserIdentifier = "" and override the previous step has been removed.

SR-D10171 · Issue 482472

Updated UtilsEmailListener to handle additional special characters in the email ID

Resolved in Pega Version 8.2.2

When the Email Listener tried to map the properties from the email body and message header to the Pega Default out-of-the-box properties or user provided text properties, the mapping worked for simple alphanumeric email IDs, but mapped only the trailing part of the address if the Email ID contained an apostrophe or single quotes. For example, "toast.'[email protected]" was mapped as "[email protected]". This was due to a missed special character in the regex pattern, and UtilsEmailListener.java has been updated to correctly handle special characters in the email address as specified in RFC 5322.

SR-D10281 · Issue 482814

Configuration settings introduced for VBD read/write consistency

Resolved in Pega Version 8.2.2

Exports of VBD data at different consistency levels showed data inconsistency between Cassandra nodes. VBD uses the default DSM consistency level of ONE for its reads and writes, which will not automatically repair data when inconsistency exists. Data inconsistencies can lead to VBD timeouts trying to load partition data. To support VBD read/write integrity, an enhancement has been added to allow configuration of VBD read/write consistency levels by way of the following DSS properties (Owning Ruleset: Pega-DecisionEngine): vbd/readConsistencyLevel and vbd/writeConsistencyLevel. R + W > N where R is the consistency level of read operations, W is the consistency level of write operations, and N is the number of replicas. These will override the default DSM read/write consistency levels (ONE).