INC-150222 · Issue 612577
Custom client-side future date validation works on mobile
Resolved in Pega Version 8.5.3
After developing a custom client side validation based on documented examples that used jquery to locate two input fields (date pickers) and added an on-change function, the validation worked as expected on the desktop but gave a validation error for any future date when using the mobile app or browser. This was an issue with the name attribute handling on mobile, and has been resolved.
INC-150325 · Issue 616994
Child case has correct context when created from smart shape
Resolved in Pega Version 8.5.3
The Cosmos Summary Panel was not always updating as expected when a child case was created via a smart shape in the current case flow; the new case opened, but the summary panel still showed the details of the previous case. This occurred when using a create case smart shape in a flow where the case is assigned to the current user, and was due to the child case assignment being opened inside the parent context. This has been resolved by ensuring the child case is opened in the correct context.
INC-150555 · Issue 620543
isDCSPA flag added to ensure correct harness after reload
Resolved in Pega Version 8.5.3
When moving from a Process Flow to a Screenflow configured with tabbedscreenflow7, the first reload caused a switch to a Perform Harness that resulted in the error "Unable to open an instance using the given inputs", and footer buttons disappeared until multiple refreshes were done. This was an issue specific to the environment configuration at the site, but to avoid future issues a code update has been made that will add the isDCSPA flag if the value is not present in the parameter page.
INC-150731 · Issue 612883
Stages list wraps in App Studio preview
Resolved in Pega Version 8.5.3
While previewing an application in App Studio, the Approval stage section which included a header containing a chevron with each of the eight stage names across the top was displayed with the center pane expanded to accommodate the header and part of the right pane content pushed off the right edge of the window. A horizontal scroll bar was also added even though the stage names were truncated and displayed with ellipses ("..."). Investigation showed that the styles targeting stages were using flex nowrap as part of custom styles generated in pyenduser, and the styles have now been updated for stages for desktop to wrap if the number of stages would otherwise extend the screen.
INC-150778 · Issue 612311
Treatment UI screen correctly refreshes on save
Resolved in Pega Version 8.5.3
In the Web Treatment screen, saving was not working as expected and the edit button was not visible. Investigation showed that whenever Web Treatment was saved after an edit, the grid was not getting refreshed and the previous treatment rule was opened instead of the new one. This was caused by the declarepage params handling in DecisionDataRecords which treated the value as a separate argument not specific to any section and resulted in empty parameters. This has been resolved by adding an additional check for the declare page in addition to the declare page parameters while processing each section of a multiple section refresh.
INC-150872 · Issue 613080
JAWS reads the tab name and the close icon details seperately
Resolved in Pega Version 8.5.3
By default, all currently opened Work Objects Close icons have the label "Close Tab", but when moving across tabs while using the JAWS screen reader, reaching a work object tab caused JAWS to read the entire tab header as "S-123 close tab". In order to improve accessibility, aria-labels will be added while setting label to the tab so the header and close icon will be read separately.
INC-151050 · Issue 610679
Added check for empty string to custom Timeline Date Range
Resolved in Pega Version 8.5.3
When using the Timeline control and selecting Date Range as a custom value, the loading icon (busy indicator) showed continuously on the screen and no other operations were possible. Selecting any Date Range other than the custom field value worked as expected. Investigation showed that the Timeline control was not working when the Date Range value was empty, which in this case was traced to a value being entered at design time and then cleared. In timeline options, the Date Range end option was checking for the value being undefined and did not consider the empty string (""); this has been resolved by adding a condition to check if the Date Range option end is an empty string.
INC-151401 · Issue 615717
Context set for progressive scroll load of dynamic layout
Resolved in Pega Version 8.5.3
When setting pagination as 'Progressively load on scroll' for a repeating dynamic layout in a section with page list as the source, scrolling resulted in a null pointer exception and no further scrolling was possible. The issue was not seen when 'Progressively scroll on user action' was used. Investigation showed the activity Reload Section was failing because of the failure in the pre-processing activity, and this has been resolved by setting the correct context before making the pagination call.
INC-151418 · Issue 610230
Authentication updated for legacy activities
Resolved in Pega Version 8.5.3
Authentication updates have been made for several legacy activities invoked via URL by custom HTML.
INC-151858 · Issue 610352
Updated currency decimal precision
Resolved in Pega Version 8.5.3