SR-D13880 · Issue 483332

Support added for using WorkPage class for FieldValue evaluation

Resolved in Pega Version 8.2.3

The Instructions provided under the Assignment details section of an assignment shape were not evaluating the FieldValue for the work object's audit history entries unless the field value was defined only at @baseclass. This was due to WorkPage class not being considered while evaluating a FieldValue, and has been resolved by modifying the InstructionsLookup control to use work class instead of the hard coded @baseclass.

SR-D14159 · Issue 493082

Toggle added for displaying exception stack trace

Resolved in Pega Version 8.2.3

When text like "%25" was added to the login URL, the full exception stack was displayed on the screen. To resolve this, when the prconfig 'initialization/displayexceptiontraceback' is set to false (default value), the system will render the status.jsp instead of error.jsp and will not populate any sensitive data in the request object. If its set to true, the system will fall back to the old approach which renders error.jsp and emits the stacktrace.

SR-D14161 · Issue 490594

XSS protection added to decryptURLString

Resolved in Pega Version 8.2.3

In order to secure against Cross-Site Scripting attacks, decryptURLString will return a blank string instead of plain text if it is not given valid encrypted text.

SR-D14521 · Issue 486528

Added support for sorting by field value instead of localized value

Resolved in Pega Version 8.2.3

In a datapage-sourced dropdown with 'group by functionality' enabled in ascending order, the values were being sorted according to their localized value and not their field value. This was a difference between templatized and non-templatized handling, and has been resolved by adding the ability to sort the group label by field value in the templatized UI.

SR-D14591 · Issue 485929

Check added to resolve intermittent console errors

Resolved in Pega Version 8.2.3

An intermittent issue where an autocomplete control was hanging after repeated use has been addressed by adding an additional check (dispElem && dispElem.parentNode) to avoid console errors.

SR-D14601 · Issue 488289

Unique ID generation added for simultaneous multiple text area boxes

Resolved in Pega Version 8.2.3

In the Interaction portal, adding a task for a interaction using a form with a character-count enabled text area worked as expected when the interaction first opened a task with the character counter text area. However, if a second version of the same task was opened before the first task was completed, the second text area was not responsive or working as expected. This was traced to the system generating the same ID attribute for both instances of the text area character counter span, and has been resolved.

SR-D14630 · Issue 491164

Thread label clipboard issue resolved for work objects using skipDCDataModelUpdation

Resolved in Pega Version 8.2.3

n some cases, when a case ID was opened in Designer studio, its corresponding thread name in clipboard was pxThreadName instead of caseID or workID. Tab labels are handled through the Declare_pyDisplay data page. Investigation showed the child page pyDisplay(Developer) of the parent page Declare_pyDisplay, which was expected to contain pyUIElements for each tab, was missing an element for the tab whose label was shown as threadName. As this error was only reproducible for work objects with the 'skipDCDataModelUpdation' property set as true in the 'pyWorkPage', this issue has been corrected by updating the show-harness activity step-2 so the 'skipDCDataModelUpdation' property value is explicitly copied from primarypage ('pyWorkPage' in this use case) to 'parameterPage'. In addition, an issue with filtering records based on Operator Preferences has been resolved by updating ActivityStatusContentHandler to use a simple Show-HTML of the same "ActivityStatusSuccess" content instead of going through an unnecessary harness execution during activity when there is no session established.

SR-D15154 · Issue 488067

CaseType picks up stage name correctly

Resolved in Pega Version 8.2.3

When adding a new stage in the Stages tab of a case type (pyDefault rule), the stages were shown as rule name instead label after saving and at runtime. Directly adding the Stages in the 'Workflow' tab of the case type showed the stage label as expected. This was traced to an issue with the current row of the table not being properly refreshed, leading to old data being submitted while saving. This has been resolved by adding an explicit "refresh current row" configuration on pyStageName under primary and alternate stage table layouts.

SR-D15216 · Issue 487678

Email parameter handling updated for greater backwards compatibility

Resolved in Pega Version 8.2.3

After a major migration, email failures were seen with the message "Error sending email: To Address not available". This was traced to a difference in handling between the old and new system versions for fetching the details of workparty for the ToParty parameter, and has been resolved by modifying the newer Work-.pzGetEmailFromParty and Work-.pzSendEmail activities to handle party role as well for greater backwards compatibility.

SR-D15242 · Issue 486124

Removed unneeded TrackSecurityChanges warning for Field Level Auditing

Resolved in Pega Version 8.2.3

When creating a TrackSecurityChanges data transform for Field level Auditing and providing the text in the source, the system produced warnings such as "The source 'Number of covered objects' is ambiguous and is being treated as text. If it is a page, add it to the Pages and Classes tab." These warnings were generated by pzIsAmbiguousSource when a rule modified to check for Top.pyModelName did not equal pyTrackSecurityChanges. Because the way the system processes the data transform for field level auditing is not the same as that used for the usual data transform, this warning is not necessary. To avoid confusion, the system has been updated with a check so warnings of the source being ambiguous will be ignored when the DT name is pyTrackSecurityChanges.