INC-150074 · Issue 613069
Corrected sorting icon accessibility when grid size is not fixed
Resolved in Pega Version 8.3.6
After configuring a table and checking the boxes for Filtering and Sorting and unchecking the fixed (pixel) size grid box, tabbing in to the grid/table using the keyboard did not bring the focus to the sorting icon /header, but instead the focus went to the filter icon. If filter was unchecked and sorting was checked, the focus went to the first row of the table. This was traced to the column headers missing the tabindex attribute when the column headers were not fixed. When the column headers were fixed, tabindex =0 was present for the column header and the sort icon was accessible. This was traced to the Freeze Header value not being updated according to Fixed Size value because it was not a fixed size grid. To resolve this, an extra condition has been added in GenerateCellContent Rule-Utility-Function to be used while checking the Freeze Header.
INC-145939 · Issue 606896
Updated handling for ID value change during REST connection creation
Resolved in Pega Version 8.5.3
When using the REST Connector Wizard to create a connector, if the ID was changed on the 4th (last) step of the Wizard and then the Create button was pressed, the screen would freeze and a display a javascript error. Investigation showed that when the ID was changed on the screen, the new value was not updated properly and subsequent function calls threw errors. This has been resolved.
INC-156802 · Issue 620674
Handling added for special characters for track changes
Resolved in Pega Version 8.5.3
After entering inverted commas ["] inside a text box configured with post value and 'refresh this section' actions, focusing out of it caused the UI to freeze. A JSON parse issue was seen in the browser console, which was traced to the domelement API not having handling for special characters in the HTML code. This has been resolved.
SR-D79113 · Issue 543721
Updated DisplayAttachment to handle SIngleClick download from Case Worker portal
Resolved in Pega Version 8.3.2
On using the script "pega.ui.HarnessActions.doAttachmentSingleClick" in the Worker portal to download attachments displayed within a screen flow, the entire application was hanging and no action was invoked even on clicking the Continue or Finish buttons of the screen flow. Whenever an attachment is downloaded using the script function pega.ui.HarnessActions.doAttachmentSingleClick() , an iframe is used and changetracker is called to communicate data between different iframes. However, the case worker portal is a single thread model while the manager and admin portals are multi threaded, which resulted in changetracker freezing on the worker portal. To resolve this, the DisplayAttachment HTML rule has been updated to build the necessary changeTrackerMap for the worker portal.
SR-D52144 · Issue 515670
When no active document is available on login, first document will be marked active
Resolved in Pega Version 8.3.2
After logging into the user portal, attempting to perform operations like (opening a case/work object, opening reports etc.) caused the browser request to spin or freeze. The only way to recover was to close and re-launch the browser window/session and re-login. This issue occurred when there was an active reportdefinition document before the browser/node crash in the tabless dynamic container(DC) portal. After recovery, the dynamic container did not recreate the report definition document but instead tried to activate the first document in the portal, which in this case was the default harness configured in the Dynamic Container. As it was not yet loaded, exceptions were thrown. To resolve this, when no active document is available, the first document will be marked as the active document.