Skip to main content

Resolved Issues

View the resolved issues for a specific Platform release.

Go to download resolved issues by patch release.

Browse release notes for a selected Pega Version.

NOTE: Enter just the Case ID number (SR or INC) in order to find the associated Support Request.

Please note: beginning with the Pega Platform 8.7.4 Patch, the Resolved Issues have moved to the Support Center.

INC-135523 · Issue 590437

Tab panel read meaningfully by screen readers

Resolved in Pega Version 8.3.5

When the tabPanel received focus with accessibility, the entire tab content was read instead of the W3 standard of only reading "Edit ". This has been resolved by ensuring the Tabpanel has the proper aria-labelledby.

INC-139023 · Issue 591165

Tab will exit portal side menu

Resolved in Pega Version 8.3.5

It is expected that the Tab key will take users out of the portal menu and to the next focusable element, but on the side navigation menu both tab and arrow keys moved to the next menu item. This caused users to have to navigate the entire menu. The correct behavior was seen for the Navigation rule when called from an Action (for example on the button). This was traced to the system using tabindex as "0" for every element in the menu, and the tabs code has been updated to exit out of the menu bar when pressed.

INC-138354 · Issue 594356

Third party cookies reminder added for Mashup in incognito browsers

Resolved in Pega Version 8.3.5

When working in incognito/private browser windows, attempting to use Mashup displayed a message indicating login credentials were not recognized ("Unknown password and/or username"). This was due to recent changes originating with the browsers regarding blocking third-party cookies which are necessary for Mashup to run. For informational purposes, a new API has been added which will check for the PegaRules cookie; if the cookie is not present, the message "Third party cookies must be enabled for Mashup to function." will be displayed. This message may be customized by configuring the setting "pega.web.config.xCookiesDisabled" with the required message.

INC-133951 · Issue 584148

Try catch added for templated refresh when

Resolved in Pega Version 8.3.5

After configuring a refresh when condition on a dynamic layout triggered by changes on D_worklist.pxResults, a component stack mismatch error was generated if client side UI template is enabled. Without templatization it worked as expected. This has been resolved by adding a try catch block to DynamicLayoutGenerator.java.

SR-D69098 · Issue 534042

Export to Excel works for for report definition with duplicate columns

Resolved in Pega Version 8.5

After adding a date column to a report definition (2nd column in the report), the data displayed correctly in the UI but Export to Excel failed with the error "Section 'pzRDExportWrapper' execution error on page '' of class 'Rule-Obj-Report-Definition'. : The Reference .pyDateValue(2) is not valid." This was traced to an out of bounds exception thrown if there were two or more columns with the same calculation. When preparing for export, the column with the duplicate calculation would not get added to the map of report UI fields. To resolve this, the system has been updated to allow report definition columns with the same calculation to be properly mapped to a UI field.

SR-D69108 · Issue 543846

Handling added for drag-and-drop with deleted report templates

Resolved in Pega Version 8.5

After adding a new report, an error appeared when trying to use drag-and-drop to add a column (Page List) from the Data Explorer in the report browser. This was traced to refactor work done to use the Record API throughout reporting: the ruleset on new reports was not being reset from a Pega- ruleset to an application ruleset, causing columns the referenced properties defined outside the platform to be rejected. This use case was missed because case types define their own report templates on creation, but in this scenario those had been deleted. To resolve this, the system has been updated to call pxChooseBestRuleset from pxShowReport in order to enable the use of properties defined in the application prior to saving the report.

SR-D91038 · Issue 553165

Corrected report with combo chart in Case Manager portal

Resolved in Pega Version 8.5

After adding the required columns a report in the report viewer and then adding a combo chart and dropping the summarized column on the y-axes and group by column on X-axis, clicking on "done editing" generated the error "pyUI.pyChart: You must have at least two Aggregate Columns in the chart series .pyUI.pyChart.pyDataAxis(1).pyChartOutputType: A Combo chart requires at least 1 Chart Type be a Column". Investigation showed that the second DataAxis page was getting deleted in the pzCleanChartDataAxis activity, causing the validation to fail. This has been resolved by adding a 'when' rule to "pzChartIsSingleY" that checks for "SingleYAxisClustered" chart and refers the same in pzCleanChartDataAxis to skip the data axis deletion.

SR-D90232 · Issue 555781

Combo charts now support conditional colors

Resolved in Pega Version 8.5

An enhancement has been added to facilitate the use of conditional colors in combination charts.

SR-D83060 · Issue 547919

Repaired History class report column sorting

Resolved in Pega Version 8.5

Attempting to sort any of the columns in a report using the History class did not render the results and the error "Cannot render the section" appeared. Tracer showed a Fail status for some OOTB activities with the message "java.lang.StringIndexOutOfBoundsException". Investigation showed the logic in pzMergeAutoGenForProp activity was failing because the pyIsFunction property was not set on the UIField pages for function columns. To resolve this, the logic for pzMergeAutoGenForProp has been modified to get pyIsFunction from the field name.

SR-D65327 · Issue 534571

Backspace keydown handler updated for all textinput modes

Resolved in Pega Version 8.5

Attempting to use the Backspace key to remove input from a number cell (either Integer or Decimal) did not work. When the action was performed by a Manager, the Backspace key works as expected. Investigation showed the logic in the keydown handler for the backspace key in pega_report_events.js was only ignoring the e.preventDefault() call when the textinput node type was text, not number or other input types. To correct this, the keydown handler has been updated so the backspace key in pega_report_events.js maintains the default backspace functionality for all textinput modes, not just those of type 'text'.

We'd prefer it if you saw us at our best.

Pega.com is not optimized for Internet Explorer. For the optimal experience, please use:

Close Deprecation Notice
Contact us