Skip to main content

Resolved Issues

View the resolved issues for a specific Platform release.

Go to download resolved issues by patch release.

Browse release notes for a selected Pega Version.

NOTE: Enter just the Case ID number (SR or INC) in order to find the associated Support Request.

Please update your bookmarks. This site will be discontinued in Dec 2024.

Pega Platform Resolved Issues for 8.1 and newer are now available on the Support Center.

SR-D69081 · Issue 532301

Handling added for null requiredskillcount on assignment

Resolved in Pega Version 8.5

If the property pxRequiredSkillCount was blank on an assignment when moved to a workbasket, it was never presented for Get Next Work. To resolve this, handling has been added which will change the null to 0 so the assignment is properly queued.

INC-121435 · Issue 563876

Handling added for null requiredskillcount on assignment

Resolved in Pega Version 8.5

If the property pxRequiredSkillCount was blank on an assignment when moved to a workbasket, it was never presented for Get Next Work. To resolve this, handling has been added which will change the null to 0 so the assignment is properly queued.

SR-D65513 · Issue 533277

URL encryption modified for ShowAllOperators

Resolved in Pega Version 8.5

In the control ShowAllOperators the call to pzEncryptURLActionString was introduced to encrypt URLs to avoid hijacking. The content of the URL relied on the pxRequestor.pxWorkGroup property which was resolved using pega:reference tags. This approach worked in versions below 8.x, but in higher versions the tags were not resolved at runtime and results were not displayed. To resolve this, the requestorWorkGroup will be treated as string and passed as parameter instead of using pega:reference tags.

SR-D73536 · Issue 538402

FetchApplicationLogo modified to Filter by rule resolution

Resolved in Pega Version 8.5

It was observed that the Report Definition rule "pzFetchApplicationLogo", referenced by Activity rule "pzLoadApplicationLogo", always returned the older version of the Binary File "webwb • pyapp-logo • svg" because it had been set to retrieve a maximum of one record and in this case the results were sorted in an order where the oldest record was at the top. As the Report Definition did not indicate any sorting, most DBMS were returning the results in no particular or predictable order. To resolve this, "Filter by rule resolution" has now been enabled for RD pzFetchApplicationLogo.

SR-D68235 · Issue 534782

Stale WorkSearchPreference data cleared when switching apps

Resolved in Pega Version 8.5

The D_pyWorkSearchPreferences data page data was not refreshing while switching between apps, causing stale data to be populated under the case search dropdown for all the applications after switching the application from one to another. This has been resolved by removing the D_pyWorkSearchPreferences data page as part of pzProcessApplicationSwitch.

SR-D88141 · Issue 550009

TemplateButton field correctly set read-only

Resolved in Pega Version 8.5

When a control was added to a section using the DX API, a pyTemplateButton field was added to the XML definition of the section with read-only set to 'false'. This has been corrected so the pyTemplate Button field does not allow input.

SR-D92352 · Issue 553617

Completed onChange will reset FileInput value to null

Resolved in Pega Version 8.5

When attaching a file using the "Select File" button, it was not possible to attach the same file after deleting it. Re-attaching the file worked as expected when using Drag and Drop. Investigation showed that the onchange event occurred only when the value of an element was changed, so in this case trying to attach the same file did not change the value of the element and did not fire the onchange. To resolve this, the value of FileInput in pzMultiFilePath Control will be set to null at the end of the onChange event so that an onChange event will be triggered next time even if the same file is added.

SR-D91834 · Issue 554425

Related cases of different types properly linked in Case Worker Portal

Resolved in Pega Version 8.5

After creating a case of type1 in the Case Worker portal, creating a case of type2 from the first case showed the case ID of the second case in the Related Work section as expected. However, after clicking on the link of the case ID of the second case from the related work section, the second case opened but the case ID of the first case was not shown in the Related work. The cases were correctly associated when the Case Manager portal was used instead. This was traced to the Case Worker clipboard continuing to hold the previous case ID thread, and has been resolved.

SR-D71475 · Issue 538721

Check added to apply values of newAssignPage.pxFormName

Resolved in Pega Version 8.5

After upgrade, trying to open existing assignments resulted in a different harness being opened. This was traced to changes in how the property newAssignPage.pxFormName was used, and has been resolved by checking whether the harnesspurpose is dynamic before setting the pxFormName. If formname is already present, the system will proceed with picking the harness from the shape.

SR-D63307 · Issue 542770

Unneeded class name filter removed from GetRelevantPropertiesForDataType

Resolved in Pega Version 8.5

Given one class with a set of properties and another class inherited from the first class containing a relevant records set for class 2, then a new harness did not show the base class fields. Investigation showed that the fields present in the parent class and marked relevant in the case were not being fetched due to pzGetRelevantPropertiesForDataType having a class name filter along with filter by rule resolution. To resolve this, the class name filter has been removed as it is not required due to the report already filtering by rule resolution and relevant class through a join.

We'd prefer it if you saw us at our best.

Pega.com is not optimized for Internet Explorer. For the optimal experience, please use:

Close Deprecation Notice
Contact us